10/23
Programming menu
Below is a list summarising the device programming functions available. For more details, see from page
15.
To access programming press
ENTER
for several seconds, the green LED remains lit and the first LED on
the LED bar lights up (function F1).
To scroll through the menu of the programming functions, use the
ENTER
key.
To return to function F1 go to function F10 and press
ENTER
+
SET
.
To exit programming go to function F10 and hold down
ENTER
for several seconds. If the parameters were
saved correctly, the LED bar lights scroll, otherwise it begins flashing until you press
SET
.
Function
number
Bar
position
Description Keys
Value
range
Factory
setting
F1
1
Regulated output type selection
SET
0
→
1
0
F2
2
Minimum distance calibration
SET
150mm
→
D.max -1
150mm
F3
3
Middle diameter calibration
See detailed description of field calibration
(page 16)
F4
4
Maximum distance calibration
SET
D.min.+1
→
1800mm
1800mm
F5 5
Setting
1
st
alarm threshold
SET
150mm
→
1800mm
1600mm
F6 6
Setting
2
nd
alarm threshold
SET
150mm
→
1800mm
1700mm
F7
7
Regulated output inversion
SET
0
→
1
0
F8
8
Led bar mode
SET
0
→
1
0
F9
9
Thermal probe exclusion
SET
0
→
1
1
F10
10
Exit menu saving the data