background image

5

- ENGLISH -

THW01B0001RX 030681 110918

5

INSTALLATION

 

      WARNING

- To adjust properly room temperature, install the thermostat 

far from heat sources, airstreams or particularly cold walls 

(thermal bridges).

- In order to grant the electrical safety, it is mandatory to 

screw the programmable thermo-hygrostat body to the wall 

mount plate through the two screws supplied which must be 

mounted in the battery holder.

- If the load controlled by the relay of the programmable 

thermo-hygrostat operates with mains voltage, the 

connection must be made via an omnipolar switch complying 

with current standards and with a contact opening of at least 

3 mm in each pole.

- Installation and electrical wirings of this appliance must be 

made  by  qualified  technicians  and  in  compliance  with  the 

current standards.

- Before wiring the appliance be sure to turn the mains power off.

The device is designed to be installed in a standard recess (or wall) 

mounted junction box with two or three modules or else directly on 

the wall using the screw anchors provided.
To install the device carry out the following steps:

Release  the  wall  mount  plate  fitted  under  the  base  of  the 

programmable thermo-hygrostat as shown in Fig. 2.

Fig. 2

1

2

1

Fix the plate directly on the wall or onto 2 or 3 module junction 

boxes by means of the two holes for screws (distance between 

centres: 60 mm or 85mm), taking care to pass the wires 

through the opening as shown in Fig. 3.

2

Fig. 3

Move the thermostat to the wall plate by fitting first the teeth 

of the base with the relevant holes of the plate and then exert 

a pressure on the device to the left side until the plastic teeth 

of the plate snap.

4

2

1

Fig. 7

Secure the bodyof the programmable thermostat to the wall 

plate using the supplied screw that is located inside the battery 

compartment (Fig.8).

5

Fig. 8

Insert the batteries (

not supplied as standard

) in the battery 

compartment (

I

 in Fig. 1); see paragraph ‘ HOW TO INSERT/

REPLACE THE BATTERIES ’.

6

QUICK GUIDE FOR SETTING THE TIME SCHEDULE

• Press button ‘ 

’.

• The display shows ‘ 

PrOG 

’ with the icon ‘ 

P

 

‘ turned on.

• Press key ‘ 

OK 

’: the display shows the word ‘ 

dAY

  ’,  the  icon           

‘ 

P

 

‘ and the squares corresponding to the flashing days.

• Press buttons ‘   ‘ and ‘   ‘ in order to choose one of the four 

days combinations available as pre-set.

• Press button ‘ 

OK 

’ to confirm the choice.

• The display shows hour 00:00 with the relevant dash, in the upside 

right, flashing.

• Press one of the following buttons to select the temperature 

regulation level desired:

 

Comfort mode

Press the ‘ 

 ‘ button.

 

Off / Antifreeze

Press the ‘   ‘ button.

 

Economy mode

Press the ‘   ‘ button.

 

Moving the time cursor

:  Press button ‘   ’ or ‘   ‘.

  Each time the button which sets the regulation mode is depressed, 

the time cursor automatically jumps into the next half hour.

• Once the time schedule for the day or group of days selected has 

been set, press button ‘ 

OK 

’.

The display will show the time schedule for the next day or group 

of days until the whole week has been covered.

• Once the time schedule for the whole week has been set, press 

button ‘ 

OK 

’. The programmable thermo-hygrostat will store the 

program into its memory and the word ‘ 

MEMO 

’ is shown on the 

display, then it will automatically quit the time schedule setting 
procedure.

Connect the remote sensor (if present) or the phone interface 

to connector ‘

C

’ shown in Fig. 6. The load for the thermostat 

section must be wired to the terminal block ‘

A

’ shown in Fig. 6, 

meanwhile the load for the hygrostat section must be wired to 

the terminal block ‘

B

’ shown in Fig. 6.

Fig. 6

A

C

B

Make electrical wirings by passing the wires through the 

rectangular opening in the wall plate (Fig. 3), and according to 

the diagram in Fig. 4 or Fig. 5.

3

Fig. 4

Fig. 5

The crossed out wheelie bins symbol on the equipment indicates that, 

at the end of its useful life, the product must be collected separately 

from general waste. Therefore, at the end of its useful life, the user 

must take the equipment to a designated electrical and electronic 

waste collection point , or return it to the dealer that, against the 

purchase of an equivalent appliance, it is obliged to collect the 

product for disposal free of charge. Appropriate differentiated waste 

collection for subsequent recycling, treatment and environment-

friendly disposal of the discarded equipment helps preventing possible 

negative environmental and health effects and encourages recycling 

of the component materials of the equipment.

Illegal disposal of the product by the user entails the application of 

sanctions provided by the regulations in force. 

DISPOSAL

According to the provisions of the following 

European directives 2011/65/EU, 2012/19/EU, and 

2003/108/CE, concerning the restriction of the use 

of certain hazardous substances in electrical and 

electronic equipment, as well as waste disposal.

Отзывы: