RDT FloodMaster RS-094-MK7 Скачать руководство пользователя страница 4

All specifications subject to change without notice.

© Copyright 2020 Reliance Detection Technologies, LLC – A Madison Company

ECN # 11386, 09/2020, MF110, RevB

203-488-2684 or 888-771-4929
[email protected]
www.RelianceDetection.com

27 Business Park Drive, Branford, CT 06405

NEED INSTALLATION OR SETUP ASSISTANCE? 
Call toll-free: 888-771-4929
www.RelianceDetection.com/support/RS-094

Warning: For use with water only. Do not install on gas line. Never install this device 

on a fire protection or fire suppression system. For indoor use only.

OUTPUT SIGNAL CONNECTIONS

The unit also provides output signal capabilities (SPDT Relay Output Contact) for connection to a home 

security panel or for use with an appropriate relay to control a secondary device, such as a pump. See 

Figure 2 for wiring diagram.
Normally Closed Circuit – Terminal Pins 3 & 4  

Normally Open Circuit – Terminal Pins 4 & 5

OPERATION & SYSTEM RESET

In the event the system activates, locate the source of the leak, remove the sensor from the water and 

dry the metal contacts on the bottom. Correct the problem causing the leak and replace the sensor in 

the desired leak detection location once again as required. Press and release the “Reset” button on the 

receiver to open the valve and begin the flow of water and gas again. The green “Power” indicator light on 

the receiver will flash once to confirm the reset. Light the water heater pilot and confirm gas flow to the 

water heater.

MAINTENANCE

Test the system annually per the function test (install step 10) to ensure correct operation and maintain 

product warranty status. At a minimum, exercise (press and release) the “Reset” button on the receiver.

EMERGENCY MANUAL VALVE OPERATION

The unit is equipped with an emergency feature for the manual rotation of the valve. Disengage the 

actuator from the valve and manually changing the valve to open or closed as follows:
  1. Turn off the main power to the transformer.
  2.  Stabilize the water feed line by grabbing it in one hand near the valve. While grasping the actuator 

housing in the other hand, pull the actuator housing away from the water feed line.

  3.  Using an appropriate hand tool (such as a pliers), clamp down on valve stem and turn in the appropriate 

direction until the desired position is achieved. Note the top of the stem is slotted to indicate valve 

position (in line with water flow indicates open valve; slot across water line indicates closed).

  4.  Before remounting the actuator, return the valve to the original position prior to the manual rotation.
  5. Remount the actuator and restore the main power to the transformer.
  6. Test for correct operation per the function test listed in install step 10.