24 VDC POWER INPUT

Insert plug from power 

supply. Rotate 1/4 turn 

clockwise to lock.

POWER INDICATOR

Glows blue when the 

product is connected to 

a valid power source.

OUTPUT LEVEL

Adjust the gain controls for the correct 

level on the OUTPUT LEVEL meters.

MICROPHONE INPUTS

Connect a microphone to the 

LEFT and RIGHT XLR jacks. 

Microphones may be either a 

dynamic or condenser type.

LINE OUTPUT

Connect to other equipment line input from either 

the RCA jacks or from the stereo MINI-jack.

PHANTOM SELECTOR

Set for mic type connected:

Dynamic mic: OFF (out) 

Condenser mic: ON (in)

STEREO OUTPUT VU METERS

LEFT and RIGHT LED VU meters monitor the unbalanced 

outputs for proper -10 dBV level. With audio present, the 

variable intensity green LED should be as bright as possible 

with the red LED flashing occasionally. (The red LED 

flashes when the output level exceeds -10 dBV.)

AUDIO COMPRESSORS

Compressors control overload and clipping 

over a wide dynamic range of input signals, 

and are normally enabled. Set the switch to 

either enable (button IN) or disable (button 

OUT) compression.

POWER CONNECTION

FIXED MOUNTING

RUBBER FEET ATTACHMENT

Insert Power Plug

Bottom View 

of chassis

Recess

Screw 

directly to flat 

surface without 

installing rubber feet.

Rotate 1/4-turn 

clockwise to lock.

Rotate 1/4-turn 

counter-clockwise 

to unlock.

Peel backing and stick the 4 rubber 

feet to chassis in recesses provided.