24 VDC POWER INPUT

Insert plug from power 

supply. Rotate 1/4 turn 

clockwise to lock.

POWER INDICATOR

Glows blue when the 

product is connected to 

a valid power source.

OUTPUT LEVEL

Adjust the gain control for the correct 

level on the OUTPUT LEVEL meter.

MICROPHONE INPUT

Connect a microphone to 

the XLR jack. Microphone 

may be either a dynamic or 

condenser type.

LINE OUTPUT

Connect to other equipment line input from either the 

RCA jacks or from the stereo MINI-jack.

PHANTOM SELECTOR

Set for mic type connected:

Dynamic mic: OFF (out) 

Condenser mic: ON (in)

OUTPUT VU METER

The LED VU meter monitors the unbalanced output for 

proper -10 dBV level. With audio present, the variable 

intensity green LED should be as bright as possible with the 

red LED flashing occasionally. (The red LED flashes when 

the output level exceeds -10 dBV.)

AUDIO COMPRESSOR

The compressor controls overload and 

clipping over a wide dynamic range of 

input signal level, and normally should be 

enabled. Set the switch to either enable 

(button IN) or disable (button OUT) 

compression.

POWER CONNECTION

FIXED MOUNTING

RUBBER FEET ATTACHMENT

Insert Power Plug

Bottom View 

of chassis

Recess

Screw 

directly to flat 

surface without 

installing rubber feet.

Rotate 1/4-turn 

clockwise to lock.

Rotate 1/4-turn 

counter-clockwise 

to unlock.

Peel backing and stick the 4 rubber 

feet to chassis in recesses provided.