![RCT 11966 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/rct/11966/11966_product-manual_1424352009.webp)
M0879.docx
| Rev 1.6 | Modified on 11/01/2018 | © Remote Control Technologies Pty Ltd
9 | 12
CALIBRATION
SETTING
NO.
DESCRIPTION
UNITS*
DEFAULT
1**
Crank time period
The time period the engine can be cranked without causing a
lockout period, adjustable between 5 and 12 seconds.
Seconds
10
2**
Max crank time period
The maximum allowable time for the engine to be cranked at
any point, adjustable between 15 and 30 seconds.
Seconds
30
3**
Lockout time period
The amount of time the controller will lock out the ability to crank
the engine after exceeding the long crank time period,
adjustable between 30 seconds and two minutes.
Seconds
60
*
Note
: The units’ column indicates the value that the setting will increase by with each increment.
**
Note
: These parameters can be changed through programming; however, this will require the use of
the
programmable controller utility
available from RCT
.
SERVICE INFORMATION
SERVICE SCHEDULE
The manufacturer recommends that the following service procedure should be performed at each machine’s
scheduled service interval.
SERVICE PROCEDURE
1. Perform a visual inspection; include the following:
a) Controller
b) Wiring connections and looms
c) Switches
2. Perform a system test as per the Operation and Use section of this manual for the operation of the
controller.
PARTS LIST
12726
OVERCRANK CONTROLLER KIT (12 V)
PART NO.
DESCRIPTION
QUANTITY
INCLUDED PARTS
SUGGESTED SPARES
11966
Overcrank Controller
1
1
1523
12 V Relay
1
1
12738
Generic Loom
1
-
11112
Blue LED
1
-
12048
Warning LED Label
1
-
12049
Overcrank Bypass Label
1
-
3543
Key Switch Head Stay Put L/H
1
-
9476
Switch Body with 1 x N/O contact
1
-
11981
LED Resistor
1
-