PRODUCT MANUAL
OVERCRANK PROTECTION CONTROLLER
Part No. 11966 | 12725 | 12726
Страница 1: ...PRODUCT MANUAL OVERCRANK PROTECTION CONTROLLER Part No 11966 12725 12726 ...
Страница 2: ...or infringements upon the rights of third parties that may result from its use All examples and diagrams shown in this manual are intended only as an aid to understanding the text not to guarantee operation RCT will accept no responsibility for actual use of the product based on these illustrative examples Please contact your nearest RCT branch for more information concerning applications in life ...
Страница 3: ...NTROLLER STATUS INDICATOR OPERATION 6 INSTALLATION GUIDE 7 WIRING CONNECTIONS 7 EXTERNAL WIRING DIAGRAM 501d 8 CALIBRATION 9 SERVICE INFORMATION 9 SERVICE SCHEDULE 9 SERVICE PROCEDURE 9 PARTS LIST 9 12726 OVERCRANK CONTROLLER LOW VOLTAGE KIT 12 V 9 12725 OVERCRANK CONTROLLER KIT 24 V 10 TECHNICAL SPECIFICATIONS 10 COMPLIANCE AND STANDARDS 10 TROUBLESHOOTING 11 GLOSSARY 11 WARRANTY 11 ...
Страница 4: ... protect the machine and other equipment in the area Do not operate any machine with a known fault and report all findings to the supervisor in writing Test and operate machine as per machine OEM and site procedures Read and understand machine and site specific operational and testing instructions PRODUCT Before applying power to the equipment the user repairer installer must read all product inst...
Страница 5: ...ter motor from over cranking The overcrank protection controller will stop the engine starter motor being cranked for an excessive amount of time and provides a cooling down period between long cranking FEATURES AND FUNCTIONS Multi voltage 12 24 V Environmentally sealed IP65 Overcrank visual warning Protects starter circuit from unnecessary damage caused by overcranking Overcrank timeout function ...
Страница 6: ...mentioned above are the default time settings Refer to the Calibration section of this manual if you require different time settings CONTROLLER STATUS INDICATOR OPERATION STATE INDICATOR SEQUENCE Battery Power up All indicators will turn on All indicators will turn off After power up the controller will revert to normal operation Status Indicator in Operation RED Fault If outputs have problems thi...
Страница 7: ...erator 4 Remove the engine start crank wire from the ignition switch and connect it to terminal 87 of the relay 5 Connect the yellow wire pin 8 to terminal 30 of the relay run a second wire from the engine start crank terminal of the ignition switch and connect the other end to terminal 30 of the relay There should now be two wires connected to terminal 30 of the relay 6 Connect the yellow blue wi...
Страница 8: ...hole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand OVERCRANK PROTECTION CONTROLLER EXTERNAL WIRING www rct net au UNCONTROLLED DOCUMENT REV 5 DWG No 501d STATUS NTS SCALE Released SHEET 1 of 1 BY RD DRN CW DATE 05 02 14 APPD DW DATE 05 02 14 STOCK CODE MH MV OCC PART NO 11966 3rd ANGLE PROJECTION ALL DIMENSIONS IN MILLIMETERS WIRE LE...
Страница 9: ...ement Note These parameters can be changed through programming however this will require the use of the programmable controller utility available from RCT SERVICE INFORMATION SERVICE SCHEDULE The manufacturer recommends that the following service procedure should be performed at each machine s scheduled service interval SERVICE PROCEDURE 1 Perform a visual inspection include the following a Contro...
Страница 10: ...gramming adjustment Refer to Calibration section COMPLIANCE AND STANDARDS RCT has an obligation as a manufacturer to comply with the regulations as required by the relevant regulatory bodies depending on the market and location This product currently complies with the following ACMA IEC 61000 6 1 2005 Electromagnetic Compatibility EMC Part 6 1 Generic Standards Immunity for Residential Commercial ...
Страница 11: ...rd CPU Central Processor Unit PIN Personal Identification Number DC Direct Current PLC Programmable Logic Controller E G For example POT Potentiometer ETR Energised To Run PPM Pulses Per Metre ETS Energised To Stop PWM Pulse Width Modulation ESD Engine Shutdown PWR Power FET Field Effect Transistor Rev Revision GND Ground RF Radio Frequency H Hours RH Relative Humidity HEX Hexadecimal Numbering Sy...
Страница 12: ...Discover more www rct global com sales rct global com AUSTRALIA 61 0 8 9353 6577 AFRICA 27 0 83 292 4246 CANADA 1 705 590 4001 RUSSIA CIS 7 910 411 11 74 SOUTH AMERICA 56 9 7387 2385 USA 1 801 938 9214 ...