 [8.2] Access to the inverter

 

 

The Solar Inverter is equipped with an internal Wi-Fi unit. To set up Solar inverter you need to 
access via Wi-Fi due to the suitable Android APP.  
The Android App is the central user interface for commissioning.                                       
It ensures easy data collection and troubleshooting. 

 

Obtaining Android App:  

Go to Google Play Store, search for “RCT Power App”, and install.

 

 

Step 

Description 

 

Activate Wi-Fi on your smartphone (or tablet 
computer). 

 

Connect with SSID identical with the name of the 
Power Storage on inverter display via Wi-Fi.  

(e.g. PSAC 6.0 PPRP). 

 
 

If the Inverter is already in a network via 
Wi-Fi, connect to the network.  

 

 

 

 

 

If you connect the first time with a device to the 
inverter you need a password.  

The password corresponds to the serial number 
of your device (see display or name plate). 

 

Start the 

„RCT Power“ APP. 

  

 

Switch to tab “Network” and press “Scan”. 

 

 

Activate “10.10.100.254“ (or if you have renamed 
the device choose this) by choosing radio button. 

 

 

If the connection is made with an inverter, the 
name is displayed on the head and the icon is 
edged. 

 

 

 

Only an example ! 

Содержание Power Storage AC 4.0

Страница 1: ...es Familiar with all applicable laws regulations standards and codes for electrical devices Familiar with safety requirements and safety related guidelines for electrical devices Familiar with work pr...

Страница 2: ...section 4 5 p 6 7 and section 7 p 9 Power Sensor section 6 p 8 Switch on Inverter switch on fuses Section 8 1 p 10 Access to the inverter via APP Steps 1 to 5 in section 8 2 p 11 Configure the invert...

Страница 3: ...ammable firm wall Room may not contain highly flammable goods liquids or gas B Protect from snow rain direct sunlight and dust Observe allowed ambient temperature 25 60 C Maximum degree of pollution P...

Страница 4: ...rical work Risk of death or injury due to electric arc Disconnecting DC plugs under load can cause electric arcs Risk of damage due to improper installation and operation or misuse Contact local utili...

Страница 5: ...y is not included 3 4 Additional Protective Grounding Material not included in delivery If required in the country of installation attach a second protective earth connection to the Power Storage Inve...

Страница 6: ...2 Serial RS485 interface 2 X100 Multifunctional relay max 24 V 1 A 3 X101 Power management 4 digital inputs for potential free relay contacts 4 X103 Digital in out S0 signals max input 24 V max output...

Страница 7: ...oning information Fig 4 RJ45 Communication Ports 5 1 Connection of RJ45 Communication Ports 5 2 Wiring of RJ45 Communication Ports Communication with Power Battery Additional Power Sensor Communicatio...

Страница 8: ...der and direction of installation is not important 3 Connect the Power Sensor to the Current Sensor communication connector Power Sensor B at the Power Storage via patch cable see Fi 4 4 For further c...

Страница 9: ...ponding network cable at least Cat5e must be connected to the Power Storage AC and the corresponding terminal preferably a router The configuration of this connection is made via the menu item Network...

Страница 10: ...storage system already exists this information can also be transmitted via LAN WLAN and thus dispenses with the RCT Power Sensor In order to make visible an external power generator on the App it mus...

Страница 11: ...mputer 2 Connect with SSID identical with the name of the Power Storage on inverter display via Wi Fi e g PSAC 6 0 PPRP If the Inverter is already in a network via Wi Fi connect to the network 3 If yo...

Страница 12: ...priate norm and apply 11 Wait during parameters are synchronizing and stored When finished press Finish Return to the main menu 12 Go to Device and click on Settings then click Battery 13 Click on Bat...

Страница 13: ...he Power Sensor has been arranged Go to the hompage online and press the symbol and check the display Current sensors are tuned 1 Note For further information on installation and operation please refe...

Страница 14: ...er phase 9 1 A 9 1 A Rated frequency 50 Hz 60 Hz Frequency range 45 Hz 65 Hz Max switch on current 13 A 0 1ms Max fault current RMS 285 mA Rated AC voltage 230V 400 V L1 L2 L3 N PE AC voltage range 18...

Страница 15: ...g altitude 2000 m Max relative humidity 4 100 condensating Typical noise 35 dB Operating temperature range 25 C 60 C 40 at full load Type of installation Wall mounting outdoor Dimensions height x widt...

Страница 16: ...RCT Power GmbH Line Eid Str 1 78467 Konstanz Deutschland Tel 49 0 7531 996 77 0 Mail info at rct power com Internet www rct power com 01 2019...

Отзывы: