RCT Power Power Storage AC 4.0 Скачать руководство пользователя страница 1

SETUP

 

Installation 

 

Power Storage AC  4.0 / 6.0  

 

This setup manual contains a short instruction required 
for installing, wiring, commissioning and operating the 
inverters. For further instructions on installing or 
operating, please refer to the detailed user manual, 
which you can access vi

www.rct-power.com

 

RCT Power GmbH reserves the right to make changes 
to specifications or documents without prior notice. 
RCT Power GmbH shall not be responsible for any 
damages resulting from use of this document.  
This document does not replace any applicable laws, 
regulations, standards or codes. 
Warranty conditions come enclosed with the device.      
No warranties can be derived from this document. 

 

 

 

Intended Product Usage

 

 

 

To prevent personal injury or property damage, 
the inverter must only be installed, wired, 
connected, commissioned, maintained and 
serviced by qualified personnel: 

 

Trained in installing electrical devices. 

• 

Familiar with all applicable laws, regulations, standards 
and codes for electrical devices. 

• 

Familiar with safety requirements and safety-related 
guidelines for electrical devices. 

• 

Familiar with work protection laws and regulations. 

• 

Using the appropriate personal protective equipment. 

 
Power Storage AC 4.0 and 6.0 are stationary 3-phase 
string inverters with integrated battery charger. These 
are used as a supplement to store surplus energy in 
PV systems. 
The stored energy of the battery is converted into grid-
compatible AC power and fed into the house network to 
cover the household consumption. 
 
They are not designed for any other application or 
connection to other devices. 
 
Any use that differs from or goes beyond the intended 
usage is considered misuse. RCT Power GmbH shall 
not be liable for any damage resulting from misuse 
 
Any misuse will terminate warranty, guarantee and 
general liability of the manufacturer. 
 

 

 

 

 

 

EN 

Symbol

 

Level of risk

 

Explanation

 

high 

medium 

low 

Immediate 

danger of death 
or serious injury 

 

 

 

Immediate 

danger of minor 

or moderate 

injury 

 

 

 

Danger of 

equipment or 

property damage 

 

 

 

 

Содержание Power Storage AC 4.0

Страница 1: ...es Familiar with all applicable laws regulations standards and codes for electrical devices Familiar with safety requirements and safety related guidelines for electrical devices Familiar with work pr...

Страница 2: ...section 4 5 p 6 7 and section 7 p 9 Power Sensor section 6 p 8 Switch on Inverter switch on fuses Section 8 1 p 10 Access to the inverter via APP Steps 1 to 5 in section 8 2 p 11 Configure the invert...

Страница 3: ...ammable firm wall Room may not contain highly flammable goods liquids or gas B Protect from snow rain direct sunlight and dust Observe allowed ambient temperature 25 60 C Maximum degree of pollution P...

Страница 4: ...rical work Risk of death or injury due to electric arc Disconnecting DC plugs under load can cause electric arcs Risk of damage due to improper installation and operation or misuse Contact local utili...

Страница 5: ...y is not included 3 4 Additional Protective Grounding Material not included in delivery If required in the country of installation attach a second protective earth connection to the Power Storage Inve...

Страница 6: ...2 Serial RS485 interface 2 X100 Multifunctional relay max 24 V 1 A 3 X101 Power management 4 digital inputs for potential free relay contacts 4 X103 Digital in out S0 signals max input 24 V max output...

Страница 7: ...oning information Fig 4 RJ45 Communication Ports 5 1 Connection of RJ45 Communication Ports 5 2 Wiring of RJ45 Communication Ports Communication with Power Battery Additional Power Sensor Communicatio...

Страница 8: ...der and direction of installation is not important 3 Connect the Power Sensor to the Current Sensor communication connector Power Sensor B at the Power Storage via patch cable see Fi 4 4 For further c...

Страница 9: ...ponding network cable at least Cat5e must be connected to the Power Storage AC and the corresponding terminal preferably a router The configuration of this connection is made via the menu item Network...

Страница 10: ...storage system already exists this information can also be transmitted via LAN WLAN and thus dispenses with the RCT Power Sensor In order to make visible an external power generator on the App it mus...

Страница 11: ...mputer 2 Connect with SSID identical with the name of the Power Storage on inverter display via Wi Fi e g PSAC 6 0 PPRP If the Inverter is already in a network via Wi Fi connect to the network 3 If yo...

Страница 12: ...priate norm and apply 11 Wait during parameters are synchronizing and stored When finished press Finish Return to the main menu 12 Go to Device and click on Settings then click Battery 13 Click on Bat...

Страница 13: ...he Power Sensor has been arranged Go to the hompage online and press the symbol and check the display Current sensors are tuned 1 Note For further information on installation and operation please refe...

Страница 14: ...er phase 9 1 A 9 1 A Rated frequency 50 Hz 60 Hz Frequency range 45 Hz 65 Hz Max switch on current 13 A 0 1ms Max fault current RMS 285 mA Rated AC voltage 230V 400 V L1 L2 L3 N PE AC voltage range 18...

Страница 15: ...g altitude 2000 m Max relative humidity 4 100 condensating Typical noise 35 dB Operating temperature range 25 C 60 C 40 at full load Type of installation Wall mounting outdoor Dimensions height x widt...

Страница 16: ...RCT Power GmbH Line Eid Str 1 78467 Konstanz Deutschland Tel 49 0 7531 996 77 0 Mail info at rct power com Internet www rct power com 01 2019...

Отзывы: