background image

11 

7

 

Disposal  

Here you will find information on the proper disposal of electrical waste.  

1 Separate collection of old appliances  

Electrical and electronic equipment that has become waste is referred to as old equipment. Owners of WEEE must dispose of 
it separately from unsorted municipal waste. In particular, WEEE does not belong in household waste, but in special 
collection and return systems.  

2 Options for the return of WEEE  

Owners of old appliances from private households can return them free of charge to the collection points of the public waste 
management authorities.   

3. data protection  

Old appliances often contain sensitive personal data. In your own interest, please note that each end user is responsible for 
deleting the data on the waste equipment to be disposed of.  

4 Meaning of the symbol "crossed-out dustbin  

 

The symbol of a crossed-out dustbin regularly displayed on electrical and electronic equipment indicates 
that the respective device must be collected separately from unsorted municipal waste at the end of its 
service life. The appliance must not be added to household waste.  

8

 

Disclaimer 

 

Although every care has been taken to ensure the accuracy and completeness of the information contained in this manual, 
no liability can be accepted for errors or omissions. 

RCT Power GmbH reserves the right to change the hardware and software features described herein at any time without 
notice. 

Warranty or liability claims of any kind are excluded by one or more of the following causes: 

 

 

Improper use or installation of the product 

 

Non-compliance with storage and transport conditions 

 

Damage in transit 

 

Operation of the unit outside the specified range 

 

Use of unsuitable tools, measuring equipment or protective equipment 

 

Installing or operating the product in an unsuitable environment 

 

Failure to observe relevant safety regulations at the place of use, during installation and commissioning 

 

Ignoring safety notices and instructions in all documents relevant to the product. 

 

Installing or operating the product under incorrect safety or protective conditions. 

 

By modifying the product or installing software without authorisation 

 

A defect in the product caused by operated or neighbouring equipment outside the permissible limits 

 

Damage due to force majeure 

 

This manual may not be reproduced, transmitted, copied or translated into other languages, in whole or in part, in any form 
or by any means, without the prior written permission of RCT Power GmbH. 

RCT Power GmbH does not accept any guarantee for damage due to faulty or lost data, due to incorrect operation or 
malfunction of the inverter, the software, additional devices or PCs. 

 

 

Содержание Power Inverter 5.0

Страница 1: ...MANUAL Power Sensor 50 100 EN ...

Страница 2: ...ecuted We reserve the right to make technical changes that improve the equipment or increase the safety standard even without a separate announcement Responsible for content RCT Power GmbH This user manual contains products and product names which are registered trademarks The mention of products and product names is used only for information purposes and does not represent product misuse Names or...

Страница 3: ...UMENT 1 2 SAFETY INSTRUCTIONS FEHLER TEXTMARKE NICHT DEFINIERT 3 PRODUCT INTRODUCTION 3 4 CONNECTION OF POWER SENSOR 6 5 TROUBLESHOOTING 10 6 DISCONNECT THE SYSTEM FROM THE POWER SUPPLY 10 7 DISPOSAL 11 8 DISCLAIMER 11 9 TECHNICAL DATA 12 ...

Страница 4: ...sensor device or product hereinafter unless specified otherwise This setup manual contains a general instruction required for installing wiring commissioning and operating the Power Sensor 50 100 The contents of the manual will be periodically updated or revised due to product development The latest manual version can be accessed via www rct power com RCT Power GmbH reserves the right to make chan...

Страница 5: ...ws regulations standards and codes for electrical devices They are familiar with safety requirements and safety related guidelines for electrical devices They are familiar with national work protection laws and regulations They know and use the appropriate personal protective equipment Safety precautions The Power Sensor 50 100 has been designed and tested strictly according to the international s...

Страница 6: ...ection 8 1 2 Please note The Power Sensor 50 100 is not designed for any other application or connection with other devices Any use that differs from or goes beyond the intended usage is considered misuse RCT Power GmbH shall not be liable for any damage resulting from misuse Any misuse will cause the termination of the warranty guarantee and general liability of the manufacturer Item Description ...

Страница 7: ...ately inform the transport company Power Sensor 50 100 Unpack box and check the content for completeness according to Fig 3 2 1 Inspect the Power Sensor unit for visible damages Contact your supplier if the delivery is incomplete or damaged Do not install connect and operate the Power Sensor if any damage was detected 1 2 3 4 Fig 3 2 1 Delivery contents of Power Sensor 50 100 Item Description 1 1x...

Страница 8: ... Power Storage 2 Split core interface 3 Split core current sensors 50A Power sensor 50 200A Power sensor 100 3 2 3 Name plate Item Description 1 Serial number 2 Technical data 3 Symbols This symbol indicates that the user manual must be read and unterstood before putting the unit into operation 1 1 3 2 3 3 3 2 ...

Страница 9: ...nts which can cause fatal electric shocks Any work which involves wiring connecting or opening the inverter or the battery housing has to be performed by qualified personnel Make sure other persons keep away from cables and inner inverter parts Risk of death or serious injury due to electric arc When the inverter is connected to a PV array which is exposed to sunlight DC voltage source high voltag...

Страница 10: ...n a top hat rail in the service entrance box Split core sensors installation Click the three current sensors around the L1 L2 and L3 wires in the service entrance box the order and direction of the current sensors installation is not important 1 2 3 ...

Страница 11: ... close the cover of the inverter Connection to Power Storage DC 8 0 10 0 Connect the power sensor to the Power Sensor socket of the Power Storage DC 8 0 10 0 using the patch cable as shown Connection to Power Storage AC Unscrew and remove cover of inverter Open cable gland and feed cables trough the holes next to the battery inputs Connect the Power Sensor to the B of the Power Storage AC main boa...

Страница 12: ...the checkbox is ticked see below Should it be necessary to rearrange the power sensor for some reason rewiring or similar please proceed as follows Sensor Configuration in operation mode Step Description 1 Start RCT Power App and connect to the device 2 Continue with Device Settings Device settings scroll down Power Sensor tuning scroll down 3 Remove the hook at Current sensors are tuned 4 The dev...

Страница 13: ... Ensure that other persons stay away from cables and internal components Step description 1 Turn the DC load break switch to 0 See Fig 1 b 2 Switch the battery off via the ON OFF switch on the master to position 0 3 Disconnect the inverter from the grid using the external circuit breaker or main switch 4 Wait 10 minutes until the capacitors are discharged 5 Disconnect the DC side PV and battery Re...

Страница 14: ...s manual no liability can be accepted for errors or omissions RCT Power GmbH reserves the right to change the hardware and software features described herein at any time without notice Warranty or liability claims of any kind are excluded by one or more of the following causes Improper use or installation of the product Non compliance with storage and transport conditions Damage in transit Operati...

Страница 15: ...ght x width x depth 91 x 72 x 44 mm Dimensions current sensors height x width x depth 41 x 26 x 26 mm 67 x 51 x 41 mm Current sensor cable length 1 m Max cable diameter current sensor 10mm 24mm IP degree of protection IP 20 Type of installation DIN rail mounting Split core Operating temperature range 5 C 40 C INTERFACE Power Storage Interface Current loop ...

Страница 16: ...13 1 2022 RCT Power GmbH Line Eid Str 1 78467 Constance Germany Tel 49 0 7531 996 77 0 Mail info at rct power com Internet www rct power com ...

Отзывы: