MAIN FEATURES

•   Automatic variable speed fan
•   Over current protection
•   Over heating protection
•   Load short circuit protection
•   Built in l.P.F. ( Low pass filter ) circuit
•   Output led indicator
•   6 Zone speaker output or all call
•   Speaker attenuator per channel by 6 step

FURTHER FEATURES

•   Input gain volume control per microphone
•   Selective phantom power per microphone
•   Din connecter for P.T.T. Microphone (VLM-100) input
•   Rca jack for LINE 4, 5 input
•   Rca jack for RECording output
•   Connect for PRE-OUT/external AMP IN
•   Equalizer per input channel
•   Telephone PAGING and NIGHT RINGER
•   2- Or 4-tone chime  

(switchable with jumper ms 1)

•   Siren switachble to alarme tone
•   Optional module connection 

 

(CR-10, TP-10, CP-10, DM-10, CDP-10 M, CDR-10 RDS) 

•   Remote control for POWER ON/OFF
•   SOFT START for battery power supply delay
•   Remote control system by RJ45 connector 

1. Digital message 
2. Chime 
3. Connection with up to 3 VLM-106/206 simultaneously

•   Auto alert announcement and AUTO POWER "ON" 

Connecting to digital message (DM-10)  
(Message first priority connecting with fire alarm)

•   Mic 1, 2, 3 priority selector switch

HAUPTMERKMALE

•   Automatische Anpassung der Lüftergeschwindigkeit
•   Kurzsschlußschutz
•   Überhitzschutz
•   Leerlaufschutz
•   Low Pass Filter
•   Ausgang LED- Pegel Anzeige
•   6 Lautsprecherkreise und Summe
•   Lautstärkereglung pro Kreis in 6 Stufen

WEITERE MERKMALE

•   MIC-Eingänge mit Gain-Regler ( Combo-Buchsen )
•   Wahlweise Phantom-Power
•   7-pol DIN-Buchse für P.T.T. Microphon (VLM-100)
•   Cinch-Buchsen für LINE-Eingänge 4,5
•   Cinch-Buchse für REC Output,unsymm., 0 db
•   PRE-OUT und AMP IN Klinkenbuchsen, 6,3 mm
•   Für jeden Eingang Bass und Höhenregelung
•   TEL-IN für PAGING IN und NIGHT RINGER
•   Elektronischer 2- oder 4-Klanggong  

(umstellbar mit Jumper MS 1 unter Leerblende)

•   Sirene umschaltbar auf Alarmton
•   Leerfeld für optionale Tonträgermodule    

(CR-10, TP-10, CP-10, DM-10, CDP-10 M, CDR-10 RDS)  

•   Fernbedienung für POWER "ON/OFF"
•   SOFT START
•   Fernsteuerung über digitale Schnittstelle RJ45 

1. Digitales Textmodul (Option) 
2. Vorgong 
3. Verbindung von mehreren VLM-106/206 gleichzeitig

•   AUTO POWER "ON" und automatische Alarmdurchsage 

über digitales Textmodul DM-10 
(Priorität von Durchsage und Feueralarm möglich)

•   Schalter für Priorität von MIC-1, 2 und 3

FEATURES

 VLZ-SERIES 

Содержание VLZ-6360 A

Страница 1: ...OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG VLZ 6360A 6480A 6600A 6 ZONE VARIO LINE ENGLISH DEUTSCH...

Страница 2: ...esen Sie die Sicherheitsanweisungen bevor Sie das Ger t in Betrieb nehmen 1 Installation nach folgenden Richtlinien Stellen Sie das Ger t immer auf eine ebene und stabile Unter che W hlen Sie eine tro...

Страница 3: ...MODULE PILOTTON MODUL 12 FM 30 ERROR MONITORING MODULE FEHLER MONITORING MODUL 14 FS 40 FREQUENCY SHIFT MODULE FREQUENZSHIFTER MODUL 15 VLZ SERIES SAMPLE APPLICATIONS ANWENDUNGSBEISPIELE 16 17 VLZ SE...

Страница 4: ...sage rst priority connecting with re alarm Mic 1 2 3 priority selector switch HAUPTMERKMALE Automatische Anpassung der L ftergeschwindigkeit Kurzsschlu schutz berhitzschutz Leerlaufschutz Low Pass Fil...

Страница 5: ...telle geeignet Achten sie aber darauf die K hlungs ffnungen nicht zu verdecken K HLUNG Blockieren sie nie die Luft ffnungen an den Seiten min 44 mm Raum um einen optimalen K hlluft u zu gew hr leisten...

Страница 6: ...Verbindung mit MASTER Regler PROTECT PROTECT FAULT FAULT SPEAKER ZONES A T T VLZ 6480 6 ZONE MIXING AMPIFIER FRONT PANEL VLZ SERIES 1 MIC LINE LEVEL Control P T T 1 Volume EQ Control P T T 1 volume co...

Страница 7: ...activate chime and volume controller 4 TELEPHONE TEL NIGHT RINGER TEL night ringer function let you hear telephon ring Via speaker Turn RINGER volume to clock otherwise for ring decrease even RINGER...

Страница 8: ...ehen 5 REC OUTPUT Recording output auf Cinchbuchsen unsymmetrisch 0dB Hiermit k nnen alle eingespeisten Signale aufge zeichnet werden Die Lautst rkeregelung erfolgt dabei ber den Regler welcher dem ei...

Страница 9: ...rd has to be 3 0 mm in diame ter and this diameter should not be any longer than 7 me ters Fuse is located in the PCB FU 902 6 AMP PRE OUT AMP IN Klinkenbuchse 6 3 mm unsymmetrisch zum Kaskadie ren mi...

Страница 10: ...0 kHz test sig nal Apart from the test of the power ampli er functio ning the speaker line is checked for breaks and short circuit faults more details see on page 11 AC POWER REMOTE Zur Fernbedienung...

Страница 11: ...ATZMODULEN WARNUNG Der Einbau von Zusatzmodulen darf nur durch Fachpersonal erfolgen Vor dem ffnen des Verst rkers den Netzstecker aus der Steckdose ziehen anderenfalls besteht die Gefahr eines elektr...

Страница 12: ...sitivity max min OSC Level FD 21 AC POWER DC FUSE FUSE INSIDE Fuse Rating T40AL 32V REMOTE DC POWER 24V 40A AC 230V 50Hz 1420W LOW IMP HIGH IMP 4 3 2 1 5 6 NIGHT RINGER PAGING IN TEL MESSAGE FIRST PRI...

Страница 13: ...kHz test tone is present at the speaker outputs 2 Measure the voltage of the 20 kHz test tone at the connection HIGH IMP and adjust it to 2 V with the trimming control OSC Level 3 Check the voltage of...

Страница 14: ...geschaltetem Verst rker Die Belastbar keit der Relaiskontakte betr gt 1 A bei max 120 V oder max 24 V ERROR MONITORING MODULE FM 30 The fault monitoring module is availab le as an accessory and is not...

Страница 15: ...k kopplung kommen mit den DIP Schaltern eine h here Fre quenzverschiebung einstellen FREQUENCY SHIFT MODULE FS 40 The anti feedback module is available as an accessory and is not supplied with the amp...

Страница 16: ...NUFACTURING AREA OR SHOP CD PLAYER LINE 4 INPUT LINE 5 INPUT ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 INFO DESK VLM 106 206 SECRETARY VLM 106 206 SUPER INTENDENT 1 6 2 5 3 4 POWER REPEAT STOP START S...

Страница 17: ...ST PRIORITY ATT OUTPUTS SPK ZONES 4 100V FD 200 Fault Detector FM 300 Fault DC AC FAN Monitor EACH ZONE 80W MAX 40 3 2 1 ON ON ON FD 200 Fault Detector FM 300 Fault DC AC FAN Monitor Remote Receiver R...

Страница 18: ...Die folgende Tabelle gibt alle m glichen Priorit ten wieder und ihre Rangfolge PRIORITY FUNCTION When shipped it is factory preset as follows pack signal priority switch FRONT PCB MS 2 Setting at SLA...

Страница 19: ...DM 10 5 SLAVE PRIORITY For operating of 2 pcs more for VLM 106 206 simul taneously one of VLM 106 206 can be set PRIORI TY and the other is set to SLAVE Then even though VLM 106 206 is operating under...

Страница 20: ...her VLM 106 206 in series 8 AUX INPUT AUX input for other audio signals e g CD Player Tape Decks MP3 Player 9 AUDIO OUT GAIN This is audio output control volume VLM 100 MICROPHON SPRECHSTELLE VLM 100...

Страница 21: ...quenzgang Less than 3dB 50Hz 20kHz Signal to Noise Ratio Rauschpegel LINE more than 100 dB A weight MIC more than 70 dB A weight T H D Klirrfaktor Less than 0 5 1kHz Power Consumption VLZ 6120A 6240A...

Страница 22: ...F E M I H C P T T A L S E T O M E R E V Y T I R O I R P E T O M E R T A T L L A L L A C M6 M5 M4 M3 M2 M1 REPEAT STOP START STOP COM G BUSY R E V I R D L A I R E S O T P L E L L A R A E T R E V N O C...

Страница 23: ...23 VLZ SERIES NOTES...

Страница 24: ...ion Ver ffentlichung und Vervielf ltigung der enthaltenen Daten auch auszugsweise nur mit unserer ausdr cklichen Genehmigung Hardware and Software speci cations subject to change without notice Techni...

Отзывы: