RCS RCS-132A Скачать руководство пользователя страница 5

RSC-132A

   

 

5

REAR PANEL CONTROLS

RÜCKSEITE

1.  AC INLET SOCKET

 

This is AC power cord socket. Please connect the power 
cord after main power switch „off“.

2.  AC FUSE hOLDER

 

This is AC fuse holder.

 

IMPORTANT NOTICE: When fuse is blown out, it should 
be replaced with the same type fuse like following table, 
if it continuous to blown out, stop replacing fuse and refer 
servicing to qualified person.

3.  DC 24 V INPUT TERMINAL

 

This is terminals for DC 24V battery power supply, when 
unexpected AC power failure. Fuse is Built in PCB F1.

4.  MEASURINg DISABLED DRY CONTACT INPUT
 

TERMINAL

 

Connection  possibility  of  an  potential-free  contact  for 
suppressing the measurement.

5.  FAULT RELAY CONTACT

 

1 normally-open relay contact when „fault“ is measured. 
(only when RSC-132A is active)

6.  MAKE CONTACT DURINg MEASUREMENT

 

2  normally-open  relay  contact  activated  during  a 
measurement.  (for  example  for  bridging  the  volume-
control)

7.  RELAY BOARD CONNECTORS

 

4  pcs  of  Relay  boards  are  acceptable  to  connect  as  a 
connector which is connecting 8 channel relay board.

8.  ChANNEL ON/OFF SwITChES

 

This is channel ON/OFF switch which is setting of check or 
not at relative channel relay board connected.

 

„ON“  position  makes  checking  at  each  channel,  „0FF“ 
position makes no checking.

1.  KALTgERÄTEBUChSE

 

Buchse für Kaltgerätenetzkabel. Bitte schalten Sie immer 
das  Gerät  am  Netzschalter  aus  wenn  sie  das  Kabel 
anschließen.

2.   230 V SIChERUNgShALTER

 

Sicherungshalter.

 

WICHTIGER  HINWEIS:  Sollte  die  Sicherung  defekt  sein, 
muss die neue Sicherung die selben Werte besitzen. Bei 
wiederholtem  Durchbrennen  setzen  Sie  bitte  keine  neue 
Sicherung ein und lassen das Gerät von einer Fachwerkstatt 
reparieren.

3.  DC 24 V EINgANg

 

Eingang für 24 V Notstromversorgung. Die Sicherung hierfür 
befindet sich im Gerät.

4.  MEASURINg DISABLED BUChSE

 

Potentialfreier Kontakt zur Deaktivierung der Messung. z.B. 
während einer Durchsage.

5.  FAULT BUChSE

 

Potentialfreier  Schließer,  welcher  im  Fehlerfall 
durchschaltet.

6.  MAKE CONTACT DURINg MEASUREMENT BUChSE

 

2  potentialfreie  Schließer,  welche  während  der  Messung 
geschlossen werden.

7.  ANSChLÜSSE FÜR DIE RELAISPLATINEN

 

Vier  15-polige  Buchsen  für  den  Anschluss  der 
Relaisplatinen.

8.  ChANNEL ON/OFF SChALTER

 

Schalter zum Aktivieren der zu messenden Linie. Nur wenn 
der  jeweilige  Schalter  auf  ON  steht  wird  die  Linie  in  der 
Messung berücksichtigt.

Содержание RCS-132A

Страница 1: ...RSC 132A...

Страница 2: ...C 132A is ready for use Sicherheitsanweisungen Lesen Sie alle Sicherheitsanweisungen bevor Sie den RSC 132A in Betrieb nehmen 1 Installation nach folgenden Richtlinien Stellen Sie den Verst rker immer...

Страница 3: ...t begin 00 minute of next hour again Pushing the more than one second minute scanning will be high speed up to the upper position automatically 4 LCD LIQUID CRYSTAL DISPLAY lt displays all information...

Страница 4: ...though one channel pushing the buzzer off button buzzer sound will stop The fault alarm can only be abolished by pressing the BUZZER 0FF button 8 POWER SWITCH Power switch for AC INPUT 5 MEMORY TASTE...

Страница 5: ...This is channel ON OFF switch which is setting of check or not at relative channel relay board connected ON position makes checking at each channel 0FF position makes no checking 1 KALTGER TEBUCHSE B...

Страница 6: ...e which disconnects from the 100 V output of the amplifier Connection only takes place after repair of the short circuit error 1 EINGANGSKLEMMEN Eingangsklemmen f r das Ausgangssignal der Endstufe 2 A...

Страница 7: ...der Status eines jeden gespeicherten Kanals angezeigt Die Messung kann jederzeit unterbrochen werden indem die Measuring disabled Buchse an der Ger ter ckseite verbunden wird Die Messung wird nach de...

Страница 8: ...Imp over Abweichung von 15 15 Line Good Abweichung von 15 25 Line Imp under Weniger als 25 Line short Bei einem Erdschluss Ground Fault Jeder Fehler wird zus tzlich durch den internen Summer und der...

Страница 9: ...t zwischen 01 und 59 Minuten einstellen Bei l ngerer Bet tigung beginnt die Anzeige schneller durchzulaufen z B Displayanzeige f r 1 Minute minimum bzw 23 Stunden und 59 Minuten maximum Time Interval...

Страница 10: ...RSC 132A 10...

Страница 11: ...Linie Imp overoderImp underkeinFehlerangezeigt Der gemessene Wert liegt somit au erhalb des definierten Bereichs internal Dip switches on the motherboard spk res Switching between impedance measuremen...

Страница 12: ...ktromagnetische Vertr glichkeit und Niederspannungsrichtlinien RCS l t alle Ger te und Produkte die den CE Richtlinien unterliegen durch zertifizierte Pr flabors testen Dadurch ist sichergestellt dass...

Отзывы: