GENERAL

 

SAFETY

 

REQUIREMENTS:

 

1.

The installation of this appliance must conform with local codes or, in the absence of

local codes, Either the 

National

 

Fuel

 

Gas

 

Code,

 

ANZI

 

Z223.1/NFPA

 

54,

 

or

 

CAN/CGA-

B149.1,

 

Natural

 

Gas

 

Installation

 

Code

 

or

 

CAN/CGA-B149.2

, Propane Installation Code.

2.

This outdoor cooking gas appliance is not intended to be installed in or on recreational

vehicles and /or boats.

3.

This outdoor cooking gas appliance is intended for use outdoors and shall not be used in

a building, garage or any other enclosed area.

4.

Minimum

 

clearance

 

of

 

16

” – 18”

 

inches

 

from

 

the

 

back

 

and

 

sides

 

of

 

the

 

Pr

o

 

Burner

to

 

adjacent

 

combustible

 

construction

 

must

 

be

 

maintained.

 

This

 

outdoor

 

cooking

 

gas

 

appliance

 

shall

 

not

 

be

 

located

 

under

 

overhead-unprotected

 

combustible

 

construction.

5.

If the use of an external electrical source is requires when installed, this outdoor cooking

gas appliance must be electrically grounded in accordance with the local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1. Keep any electrical supply cord, or the fuel supply hose away
from any heated surfaces.

6.

Keep your Pr

o

 Burner in an area clear and free from combustible materials, gasoline

and other flammable vapors and liquids.

7.

DO NOT obstruct the flow of combustion and ventilation air to this appliance. Keep the

ventilation openings of the cylinder enclosure free and clear from debris.

8.

Check all gas connections for leaks with soapy water solution and brush. Never use an

open flame to test for gas leaks.

9.

Check flexible hoses for cuts and wear that may affect the safety before each use.

10.

Never use the Pr

o

 Burner in a windy area.

11.

Never use the Pr

o

 Burner without the drip pan installed and push all the way to the

back of the Power Burner. Without the drip pan, hot liquid and debris could leak downward
and could produce a fire hazard.

12.

CALIFORNIA PROPOSITION 65-WARNING: The burning of gas cooking fuel

generates some by-products which are on the list of substances known by the State of
California to cause cancer or reproductive harm. California law requires businesses to
warn customers of potential exposure to such substances. To minimize exposure to these
substances always operate this unit according to the use and care manual, ensuring you
provide good ventilation when cooking with gas.

NOTE:  In Massachusetts: All gas products must be installed using a 

“Massachusetts” licensed 

plumber or gas fitter. A 

“T” Handle type manual gas valve must be installed in the gas supply 

line to this appliance. This applies to permanently installed natural gas and propane 
installations. This does not apply to propane portable installations using a 20-pound tank. 

Содержание PRO RSB3A

Страница 1: ...he latest National Fuel Gas Code ANSI Z223 1 NFPA 54 and Natural Gas and Propane Storage and Handling Installation Code CSA B149 1 This appliance and its individual shutoff valves must be disconnected from the gas supply piping system when testing the system at pressures in excess of psig 3 5 kPa This appliance must be isolated from the gas supply piping system by closing its individual manual shu...

Страница 2: ...OFESSIONAL BUILDERS INSTALLERS For Safety have inspected by your local city Gas Company and Fire Department before use This is NOT an indoor appliance for outdoor use only Do not install into a combustible cabinet without an insulating liner LJRSB3 CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuel generates some by products which are on the list of substances which are known by the...

Страница 3: ...e vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debris 8 Check all gas connections for leaks with soapy water solution and brush Never use an open flame to test for gas leaks 9 Check flexible hoses for cuts and wear that may affect the safety before each use 10 Never use ...

Страница 4: ...f countertop on each side and back to Support the unit Note We recommend you build the enclosure for the power burner 6 12 15 2 cm 30 5 cm LOWER than your countertop This will ensure a safer environment when using tall cooking pots like the turkey fryer which can hold 40lbs of hot flammable oil Please make sure that you do not overfill large pots of oil for the oil will spill over and catch on fir...

Страница 5: ...10 water column and is for use with L P gas only If unit is NOT supplied with regulator please make sure that all requirements are met for the type of regulator required Use part number RONHK L P GAS SAFETY REQUIREMENT The LP gas supply cylinder must be constructed and marked in accordance with the Specifications for LP gas Cylinders of the U S Department of Transportation D O T or the National St...

Страница 6: ...owing a One side of the enclosure shall be fully open or b For an enclosure having four sides a top and a bottom At least two ventilation openings at cylinder valve level shall be provided in the sidewall equally sized spaced at 180 degrees 3 14 rad and unobstructed Each opening shall have a total free area of not less than 1 2 square inch per pound 7 1 cm2 kg of stored fuel capacity and not less ...

Страница 7: ... to the cap to the underside of the cap If the disc 1 2 in diameter of the pin is close to the cap then the regulator is set for natural gas If the disc is at the tip of the pin away from the brass cap the regulator is set for system LP application To convert to natural gas remove the plastic conversion pin and invert and replace it back in a manner such that the disc is close to the brass cap For...

Страница 8: ...solution of soap and water in a spray bottle 50 solution 2 Confirm that all control knobs are in the off position 3 Turn the main gas supply valve ON 4 Apply the leak test solution by spraying on all of the pipe joints fittings and hose 5 As gas Leak is detected when a There is a faint smell of gas and or b There is bubbles around the connections 6 DO NOT ATTEMPT TO IGNITE THE BURNER 7 Turn off th...

Страница 9: ...er to adjacent Vertical combustible construction must be maintained CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION A minimum clearance of 1 from the back of the Pro Burner Above cooking surface to non combustible construction is required A minimum of 1 clearance to the sides of the Pro Burner above cooking surface to non Combustible construction is recommended NOTE DO NOT USE THIS APPLIANCE UNDER OVERHE...

Страница 10: ......

Страница 11: ...e removed by using a mild abrasive pad like Scotch Brite with a stainless steel cleaner Use the mildest cleaner and always scrub in the direction of the grain Do not use steel wool to clean the Pro Burner Do not use abrasives on the polished highlights Be extra careful when cleaning around the highlights Metal polisher or mild chrome cleaner can be used to bring back the luster on highlights To to...

Страница 12: ...BURNER IF YOU SMELL GAS 2 WARNING IT IS CRITICAL THAT THE GAS BURNERS ARE PROPERLY INSTALLED WITH THEIR ORIFICES INSIDE THE BURNERS AIR SHUTTERS If not properly installed gas may leak outside of the burner that could lead to fire potential damage to your Pro Burner and bodily injury Inspect the gas supply piping or hose prior to turning the gas ON If there is evidence of cuts wear or abrasion it m...

Страница 13: ...er Lighting Instructions The burners can be lit manually using a lighted long match taper or long BBQ lighter 1 Push and turn the knob counter clock wise past the CLICK position Hold the knob pushed in for 5 seconds 2 Insert a lit match or BBQ lighter thru the grates and near the top of the burner Once you see or hear a flame you can release the knob NOTE if the burner does not ignite for the firs...

Страница 14: ......

Страница 15: ... Steel 1 1 21 RSB3A020 Basin Frame Back Connection Board 1 1 22 RSB3A021 Basin Frame Right Side Panel 1 1 23 RSB3A022 Drip tray 1 1 24 RSB1011 Ignition Wire L 240mm 1 1 25 RSB3A023 Ignition Wire L 330mm 1 1 26 RSB3A024 SS Ripple Tube L 325mm Φ9mm 2 2 RSB3A025 Tube Burner Orifice Φ1 8 LP 1 RSB3A026 Tube Burner Orifice Φ3 45 NG 1 28 RSB3A027 Orifice Fitting Nut 1 1 29 RSB3A028 Orifice Mounting Plate...

Страница 16: ...ay occur Improper maintenance salt spray chemicals pesticides will effect the look and integrity of the components RCS will not be responsible for any damage caused as a result of not following owner s manual instructions This non transferable warranty is limited to the replacement of original one time defective parts does not include shipping and labor to remove or install replacement parts if ne...

Отзывы: