Rcom PX-20RD Скачать руководство пользователя страница 2

Digital Incubator 

16. How to calibrate Temp.(Humidity)

13. How to Terminate Incubation

14. Incubator Initialization

15. How to Clean after Hatching

12. How to turn off Humidification Function

17. Specification

www.R-com.co.kr

Professional

PX-20RD

professional

How to calibrate : Fill vermiculite to three fourths of the internal tray. Fix temperature or hygrometer at 2 cm above

the bottom of the tray and operate it for one hour before starting its calibration.  

This calibration function is to reset the temperature and humidity of the incubator to correct values using

your thermometer and hygrometer. It is better not to calibrate the incubator as normal thermometer and

hygrometer are not reliable than incubator factory setting.

 Be sure to check        CAUTIONS before you calibrate temperature or humidity.

( ALL RESET )

For returning to the factory setting

▶ 

If you want to return to the initial set values, please follow this sequence.

      1) Select All Reset at SET UP mode

      2) Press Enter 

      3) Press OK

 Unlock three of locking buttons at the front and back of incubator,

     and disassemble the incubator.

Do not clean the product with organic solvents

such as benzene and paint thinner.

Do not inflict an impact to the humidification heating part 

.

Or, it will be damaged.

Temp. Accuracy
Working Temperature

Ideal : 22

 ~ 25

                Min. 20

 / Max. 26

Power

Humidity Limits

± 

0.5

Temp. limits

20

 ~ 42

 (68

~107.6

)

AC 100V~120V, 50/60Hz   /   AC 220V~240V, 50/60Hz

40% ~ 95%    ( It can be changed according to the conditions )

Humidity Accuracy

± 

5%

10~120 Eggs Available at once

Capacity
Net Weight
Size

4.5 Kg 

Fuse Standard

250V 2.0A (

Ø

5

×

20mm) 

(W)500

×

(L)410

×

(H)160 (mm)

Power Consumption

Average  48W    

  

COMPANY 

  

TEL

  

FAX

  

E-MAIL

: #612 DukAm-Ri, JuChon-Myeon, 

: GimHae-City, GyeongNam, KOREA

: 82-55-337-2560 (Direct to sales team)

: 82-55-337-2561-3, 2567 (Office)

: 82-55-337-2568

: [email protected] ( Sales team )

Visit our web site (www.r-com.co.kr) for more information

on our products and other informations.

Update of information : download the necessary information

from resource room in Rcom homepage.
R-com digital reptile incubator is designed for easy and 

convenient use. 

For the improvement of the functions of the incubator, design, 

how to use, etc. can be changed without notice in advance.

 If you press MENU button on incubation period, 

" System finish Are you sure ? "

 messgae will show.

 Select YES with UP / DOWN button, and then ENTER button.

 Pull out the electric cord from connecting jack, 

     and also take out the plug from the outlet.

▶ 

In case of you operate humidification function, there can be moss 

    on the humidification heating part 

. It doesn't effect in function,

    and you just need to clean it with soft brush after hatching. 

WATER

▶ 

Disassemble the incubator. The bottom part shall be thoroughly cleaned

     with water and dried.The upper parts shall be naturally dried in order to

     remove moisture inside of the incubator.

     Assemble the parts in the reverse order of disassembly.  

CAUTIONS

▶ 

You can turn off humidification function when you don't fill water with your incubation 

     or when you need low humidity incubaion under 40%. 

▶ 

Press "QUICK SET" button twice, and ress DOWN button until OFF indicated at humidity setting. 

    Then, press ENTER button. (OFF will show when the humidity is under 40%.) 

Select

the Species

of Reptile

2 Sec.

Temp. Setting

Humid. Setting

Daily Temp. Gap Setting

Screen

on Incubation

Screen

on Incubation

Select

the Species of Reptile

2 times

Once: Temp. Setting

Twice: Humidity Setting

Three times: Daily Temp. Gap setting

UNDER 40%

REFER TO "HOW TO START INCUBATION" FOR MORE INFORMATION.

"All Reset" 


℃↔℉

"OFF"

MENU

MENU

QUICK SET

QUICK SET

QUICK SET

ENTER

ENTER

ENTER

UP

DOWN

UP

DOWN

UP

DOWN

UP

DOWN

UP

DOWN

UP

DOWN

SET UP

BACK

DOWN

SET UP

BACK

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

System finish 
Are you sure?

Automatic Mode

Incubation

Other(Manual) Mode

Incubation 

How to change Setting under Incubation

(QUICK SET)

Incubation

Termination

Incubator Initialization

(Factory Setting)

 

 

 

 How to change

How to turn off 

Humidification Function

(In case of low humidity incubation)

Select YES

[ Hi-Temp Cycle 

Daily Temp. Gap- Time Setting Screen ]

[ Hi-Temp Set 

Daily Temp. Gap- Temperature Setting Screen ]

Auto incubation

QUICK SET

 

button (Selection of Reptiles)

ENTER button (Auto incubation starts after two seconds)

 

ENTER button

OTHER (MANUAL) incubation 

MENU button

UP/DOWN button 

(Selection of Reptiles)

The reptile incubation temp 

 on the menu screen

is memorized in the micro chips. User can 
optionally change the incubation temperatures.
(Initial settings: depending on types of reptiles.)

The reptile incubation Humidity 

 on 

the menu screen is memorized in the micro chips.
User can optionally change the incubation Humidity. 
(Initial settings: depending on types of reptiles.)

Daily Temp. Gap function 

 is to make 

the environment of incubator to be the hottest period 
in the day by user. User can input temperature and
time to make the optimum environments for incubation 
of reptiles. (Initial settings: 

 three hours.) 

 Incubation environments such as temperature, humidity, egg rotation, etc. are automatically controlled 

    in automatic mode. User only needs to select type of reptile. User can change incubation environment 

    if it is necessary. 

[ Humidity setting screen ]

[ Temperature setting screen ]

Incubation completion 

(under incubation)

Temperature setting

Humidity setting

Daily Temp. Gap- Temperature Setting

Daily Temp. Gap- Time Setting

It increases the daytime temperature by set temperature 

and the daytime period by set time 

 in the above STEP 3. 

In case of reptiles, it is quite often to set the temperature 
higher than the incubation temperature by 1.5

(Initial settings: depending on types of reptiles 

.)

 

QUICK SET 

button

   This button is used to reset the incubation environment
 (temperature, humidity, daytime temperature) during 
 auto or manual incubation. If 

QUICK SET

 button is pressed, 

temperature window blinks in the incubation progressing screen.
 When changing temperature, set the temperature with
 up/down button and press enter button after resetting.
 It will be then stored and converted to incubation screen
 after five seconds.

[ Daily Temp. Gap Setting Screen ]

Hi-Temp Set

26.1

80

0.0

3H

24 Hour

Temperature

Chameleon

26.1℃

NEXT

NEXT

Humidity

Chameleon

80%

NEXT

Hi-Temp Cycle 

Chameleon

3 Hour

Hi-Temp Set 

Chameleon

0.0℃

START

**Choose a kind**

* Chameleon

* Snake

* Alligator

* Gecko

* Turtle

* Tortoise

* Others

Eg.) In case of reptiles, their incubation temperature
 is 26.1

. If the daytime period is set to three hours

 and daytime temperature to 1.5

,

 the incubation temperature changes from 26.1

 

to 27.6

 for three hours once a day.

Chameleon

26.1

80

3Hr
0.0

Chameleon

26.1

80

3Hr
0.0

Others

37.5

55

3Hr
0.0

System finish
Are you sure?

YES

 

Auto Incubation:

 

    Optimum incubation conditions for the species of reptiles are memorized in micro chip. 
    With this function, you can easily operate this incubator. 
    Select the species of reptile at MENU screen with  QUICK SET button, 
    and press ENTER button for about 2 sec. for starting incubation.

 

Other (Manual ) Incubation: 

    Other (Manual) incubation is for incubating the species of reptiles which is not memorized in the incubator. 
    User can set the incubation condition according to their needs. (LCD Display will indicate as the graph above.) 
    Press MENU button at basic screen, and select "Others" with UP/DOWN button, and then ENTER button.
    Set the temperature, humidity, and daily temperature gap as your needs and press ENTER button. 

 You shift to next mode with pressing 

QUICK SET

 button 1 to 4 times.   

    You can also use it when you want to check incubation conditions under incubation.

10. Easy Function Operation

Incubation starts.

 Temperature setting 

 Temperature Setting-

     Incubation Temp. Setting

Humidity setting

 Humidity Setting- 

     Incubation Humidity Setting

 Daily Temp. Gap Setting

 

 Daily Temp. Gap - Time Setting

ENTER button 

(incubation completion)

 MENU button 

UP/DOWN button

 ("yes" selection)

 Daily Temp. Gap - Temperature Setting

HOME screen before 

starting incubation

MANU screen

Screen showing 

incubation is in progress

Screen showing incubation 

of other 

Reptiles

 is in progress

Screen showing 

completion of incubation 

 

What is Daily Temperature Gap Function? 

     This function is for making the incubation condition same with natural conditions. 
     It creats the highest temperature time zone by sun in nature artificially. 
     This function helps the hatching rate raise with optimum incubation conditions by the
     user directly set the proper temperature and time.  

11. How to start incubation by Auto or Manual

  If you leave the incubator alone without drying water after high humidity incubation, 
  the water inside of incubator condense and make waterdrop at the LCD display or 
  control device. For preventing this problem, disassemble main body 1 and 2, and 
  dry completely before storing. ( You can dry the incubator as operating the 
  incubator for about 1 to 2 hours after removing water.)

 If you do not want to change the incubation environment, press 

QUICK SET

 button to move to the next stage. 

This will be converted to incubation screen after five seconds.

back

 After start incubation, press SET UP button and go to T.CAL on incubation process. 

    If you press ENTER here ' WARNING ' will show on LCD. It goes to calibration Mode automatically 

    after 5 sec. Then, calibrate the temperature with UP/ DOWN button and press ENTER button for saving.

    ( How to calibrate Humidity : It is same with the way calibrating temperature on H.CAL ) 