R-COD 500 & 500 IR 

Installing, Commissioning, Using

 

The manual describes how to mount, connect, program and 
use the devices.  

Содержание R-COD 500

Страница 1: ...176 27 J rf lla tel 08 546 560 00 info rco se www rco se 2021 RCO Security AB All rights reserved February 2021 R COD 500 500 IR Installing Commissioning Using The manual describes how to mount connec...

Страница 2: ...th recessed box 6 Connection 7 Commissioning 8 Overview 8 Activate IR codes R COD 500 IR 8 Reset individual IR codes R COD 500 IR 9 General information about programming R COD 500 and R COD 500 IR 10...

Страница 3: ...OD 500 front panel R COD 500 IR front panel The red figure blinks when buttons are pressed and shines steadily when the unit is in menu mode These light up when the door is unlocked and when programmi...

Страница 4: ...doors by using the keypad to enter one of the programmed access codes Each time a button is pressed the left symbol blinks When a valid access code is entered the door unlocks and the two right symbol...

Страница 5: ...such as fluorescent lamps or low energy lamps If access codes 5 8 are not going to be time controlled pins 3 and 4 on terminal P1 must be connected Otherwise the codes will not work Contact mail servi...

Страница 6: ...and the unit s mounting plate 4 screws For best protection from vandalism mount the recessed box as close to the surface or spacers as possible 2 Connect the terminal block Lock the reader into place...

Страница 7: ...access code or IR code is entered received and the connection between pins 6 and 8 is broken Button P1 5 Connecting terminals 4 and 5 activates the strike relay for the specified door opening time Tim...

Страница 8: ...des using switch SW1 on the circuit board ON IR code activated OFF IR code not activated Use the procedure 1 Set all switches on SW1 to ON 2 Power up All IR codes are reset 3 Set SW1 8 to OFF 4 Test t...

Страница 9: ...RC212 7 Not used Normally set to OFF 8 Resets codes See instructions Reset individual IR codes R COD 500 IR 1 Disconnect the unit from power 2 Set the terminal for each IR code to be reset SW1 1 5 to...

Страница 10: ...looks like after you do the step Off operating mode Red LED shining programming mode Middle green LED shining Righthand green LED shining1 Changing the system code The system code is used to enter the...

Страница 11: ...k See page 7 1 8 4 Enter the access code Confirm by pressing A beep confirms code 5 Program additional access codes repeat steps 3 4 6 Press to return to the main menu 7 Return to operating mode by pr...

Страница 12: ...scription Quick guide Indication 1 Enter the system code default 1 2 3 4 x x x x 2 Select menu 5 Confirm by pressing 5 3 Enter the time in minutes and seconds Example 0115 1 minute and 15 seconds The...

Страница 13: ...known Description Quick guide Indication 1 Enter the system code default 1 2 3 4 x x x x 2 Select menu 9 Confirm by pressing 9 3 Press 1 for master reset 1 4 Confirm by pressing A beep confirms that t...

Страница 14: ...tal 50 71 IR 66 mA Temperature range at 24 V AC and max power consumption 30 70 C Current at 24 V DC Relay single pole 1 A Number of access codes 8 st Number of IR codes only R COD 500 IR 5 st Reading...