12/24VDC 

16

}

}

}

Trigger Delay - 0-7 Seconds

Relay 1 Delay - 0-63 Seconds

Relay 2 Delay - 0-63 Seconds

Timer Example

The timer is required to activate a sounder attached to relay 1 for
15 seconds with no trigger delay. After 15 seconds the timer will
activate relay 2 for 5 seconds to unlock the door.

FIG. 2 – TM3X DIP Switch Settings

Specifications

MECHANICAL:

ELECTRICAL:

ENVIRONMENTAL: 

Dimensions:

Current Consumption - Active:  70mA

Product is not for use in 

Length: 3.00”

76mm

Current Consumption - Idle:  12mA

outdoor environments.

Width: 2.10”

51mm

Relay Rating: 2A @ 24VDC

Height: 0.65”

22mm

TD3 Timer Troubleshooting Guide

PROBLEM

SOLUTION

Relay does not trigger when powered.

The relay sits at idle when powered up. To start the timing
sequence, the Trigger terminal (T) must be shorted to Ground 
(-) for the amount of time set by trigger delay.

Timer board appears to be quietly “squealing”

Timing for the TD3 is controlled by a quartz crystal that 

when triggered.

oscillates. This is not serious; occasionally quartz crystals 
emit a sound when oscillating. This will not damage the 
timer or hinder its operation.

2

TM3X Installation Instructions (con’t)

©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected] 

Содержание TM3X

Страница 1: ...ERFORD CONTROLS INT L CORP WWW RUTHERFORDCONTROLS COM USA 2517 SQUADRON COURT SUITE 104 VIRGINIA BEACH VA 23453 CANADA 210 SHEARSON CRESCENT CAMBRIDGE ON N1T 1J6 PHONE 1 800 265 6630 519 621 7651 FAX 1 800 482 9795 519 621 7939 E MAIL SALES RUTHERFORDCONTROLS COM Instructions 1 Mount the timer board in a suitable location using the supplied double sided adhesive 2 Set DIP switches for voltage sele...

Страница 2: ... 0 65 22mm TD3 Timer Troubleshooting Guide PROBLEM SOLUTION Relay does not trigger when powered The relay sits at idle when powered up To start the timing sequence the Trigger terminal T must be shorted to Ground for the amount of time set by trigger delay Timer board appears to be quietly squealing Timing for the TD3 is controlled by a quartz crystal that when triggered oscillates This is not ser...

Страница 3: ...k Nuisance Delay Operates as RCI TD4 The trigger input must be active for 3 seconds in order to start an irreversible process that will activate relay within 12 seconds Setting shown 3s trigger 12s delay with sounder 2s signal to power supply OFF ON T C NO NC NC NO C TM3X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12 24VDC Sounder Trigger Power Supply Over ride OFF ON T C NO NC NC NO C TM3X 1 2 3 4 5 ...

Страница 4: ...age to which the wire will be subjected Normally the wire rating is three to six times greater than the maximum voltage to be applied to the wire Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 75...

Отзывы: