RCI TM3X Скачать руководство пользователя страница 1

Features

• Three adjustable, microprocessor controlled 

sequential timers

>  Trigger Delay – 0-7secs
>  Timer#1 – 0-63secs
>  Timer#2 – 0-63secs

• Two separately controlled SPDT relays each rated 

2A @ 24VDC

• 12 or 24VDC operation easily selectable by 

DIP switch

• LED status indicators for each relay
• Negative Trigger

OFF  -  ON

LED RELAY #1

LED RELAY#2

T

C

NO

NC

NC
NO

C

-

+

TM3X

1

2

3

4

5

6

7

8

9

10

11

12
13

14

15

16

}

Relay #2

}

Relay #1

I N S T A L L A T I O N

TM3X

Timer Boards

®

ISTM3X

PCN110045

R07/11SH

©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected] 

Instructions

1.

Mount the timer board in a suitable location using the
supplied double-sided adhesive. 

2.

Set DIP switches for voltage selection and time delay
requirements before applying power.

3.

Wire power, trigger and relay wiring as needed. 
(See Application Notes for details)

4.

Test relay and time delay operation by activating
trigger while monitoring LED status indicators for
proper operation.  

FIG. 1 – TM3X Timer Board

Содержание TM3X

Страница 1: ...ERFORD CONTROLS INT L CORP WWW RUTHERFORDCONTROLS COM USA 2517 SQUADRON COURT SUITE 104 VIRGINIA BEACH VA 23453 CANADA 210 SHEARSON CRESCENT CAMBRIDGE ON N1T 1J6 PHONE 1 800 265 6630 519 621 7651 FAX 1 800 482 9795 519 621 7939 E MAIL SALES RUTHERFORDCONTROLS COM Instructions 1 Mount the timer board in a suitable location using the supplied double sided adhesive 2 Set DIP switches for voltage sele...

Страница 2: ... 0 65 22mm TD3 Timer Troubleshooting Guide PROBLEM SOLUTION Relay does not trigger when powered The relay sits at idle when powered up To start the timing sequence the Trigger terminal T must be shorted to Ground for the amount of time set by trigger delay Timer board appears to be quietly squealing Timing for the TD3 is controlled by a quartz crystal that when triggered oscillates This is not ser...

Страница 3: ...k Nuisance Delay Operates as RCI TD4 The trigger input must be active for 3 seconds in order to start an irreversible process that will activate relay within 12 seconds Setting shown 3s trigger 12s delay with sounder 2s signal to power supply OFF ON T C NO NC NC NO C TM3X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12 24VDC Sounder Trigger Power Supply Over ride OFF ON T C NO NC NC NO C TM3X 1 2 3 4 5 ...

Страница 4: ...age to which the wire will be subjected Normally the wire rating is three to six times greater than the maximum voltage to be applied to the wire Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 75...

Отзывы: