I N S T A L L A T I O N
9321/23
Easy Read-Prox
®
Reader
Fig. 1
Fig. 2
©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com
usA: 2517 sQuAdRon couRt, suIte 104, VIRGInIA BeAch, VA 23453 • cAnAdA: 210 sheARson cRescent, cAmBRIdGe, on n1t 1j6
Phone: • 1.800.265.6630 • 519.621.7651 • fAX: • 519.621.7939 • e-mAIl: [email protected]
Is9321/23
R08/13cA
In or Out...we make it Easy!
®
Where to install proximity readers
Low to high traffic doors
Interior or exterior doors
Narrow door frames
Inside walls
Architecturally sensitive installations
Where NOT to install proximity readers
Behind metal – RF will not penetrate
On a ferrous metal surface – diminishes read range
Near TVs or monitors – RF will interfere with reader
NOTE: READER IS WEATHER RESISTANT. Do not apply sealant or gaskets to the back of the reader, as this may cause
condensation build up and adversely affect reader operation.
9321 Slimline
1. Select appropriate space on wall for reader installation.
Ensure that there are no hidden electrical hazards prior to
drilling.
2. Drill hole for reader wiring to pass through.
3. Remove changeable cover from reader if necessary. Cover
is removed by prying off from the bottom of cover only.
4. Pass the readers 8 wires through hole.
5. Hold reader against wall with LED’s at bottom, mark
position of three mounting holes.
6. Drill the three mounting holes as appropriate for the type of
fasteners being used.
7. Install / level the reader and secure with three mounting
screws.
8. Install removable cover by engaging top tab and pivoting
cover down over reader. Cover should snap in place when
installed properly.
9. Cover is secured with single screw (provided) on lower
edge of cover.
Important: Cover screw must not be longer than 1/4” or
internal damage will result, voiding warranty.
9323 Micro
1. Select appropriate space on wall for reader installation.
Ensure that there are no hidden electrical hazards prior to
drilling.
2. Holding reader back plate against wall, mark position for
two screw holes and center hole for reader.
3. Drill center hole 13/16” (7/8” max) in diameter. If wall is
not hollow, ensure depth of the hole is at least 2-3/4” deep
to prevent damaging reader/wiring.
4. Drill two smaller mounting holes as appropriate for type of
fastener being used.
5. If necessary, drill hole through wall for wiring to pass
through.
6. Screw back plate onto reader until flush with front of
reader.
7. Pass reader wires through hole and out other side as
appropriate.
8. Insert reader into hole being careful not to damage wiring.
Secure back plate with two screws provided.
9. Snap the appropriate colored cap over the back plate by
engaging one side and press the other side until it snaps
securely in place.
Mounting Instructions