Fig. 9 Wiring a device/changing the jumpers to operate with the interior 9325i keypad.
©2010 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM
USA: 2697 INTERNATIONAL PARKWAY, PKWY 5, VIRGINIA BEACH, VA 23452 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON N1T 1J6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: [email protected]
9325 Keypad Installation Instructions
(Continued)
Power
–
+
J3
J2
J4
Output Type J2 J3 J4
Relay On
Off
Off
12VDC Off
On
On
+
–
Relay
Exit Button
N/O Pushbutton
(If Required)
+
–
White
Wires
Gray
Wires
12VDC Power Supply
1
4
7
*
2
3
5
6
8
9
0
#
The RCI 9325i keypad can be used to directly control an
electromagnetic lock or electric door strike by changing the
output. Model number 9325i is preset at factory default with
output configured as SPST N/O relay. By changing the
jumpers on the back of the keypad as shown, the output
terminals can be reconfigured to supply 12VDC power
directly to the locking device. Note: Polarity must be
observed.
Important: Remove power to keypad before changing jumper
settings. Failure to remove power may cause damage to
keypad, voiding warranty.
12 VDC Power Suppy
N/O Pushbutton
(If Required)
Black Wire
J3
J2
J4
Fig. 8 Typical wiring of a door strike through the interior
9325i relay.
Fig. 7 Typical wiring of a door strike through the
exterior 9325e relay.
Black/
White
Wire
Black
Note: To use the 9325 Keypad with an electric strike, the output relay must be programmed as Fail Locked. See programming
instructions on p. 3. For use with an electromagnetic lock, see Figs. 9, 10 and 11.
Power
Exit
Button
Relay
White
White
6