9212i Keypad Installation Instructions 

(Continued)

©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com

USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAmBRIDGE, ON  N1T 1j6 

 PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-mAIl: SAlES@RUTHERFORDCONTROlS.COm

 

WHITE

ORANGE

WHITE/ORANGE

BROWN

WHITE/YELLOW

BLACK

RED

WHITE/BLACK

WHITE/RED

WHITE/BLUE

WARNING: Plug this harness in with the leads 
facing down! Permanent damage may result if 
incorrectly inserted.

Fig. 6  9212i Wiring Harness. 

WARNING: Plug this harness in with the leads facing down! Permanent damage may result if incorrectly inserted.

Wire Color 

Wire Function

White 

Not Used

White/Blue 

Output 3 (50mA sink to ground)

White/Red 

Output 2 (50mA sink to ground)

Orange 

Output 4/panic (50mA sink to ground)

Brown 

Remote Triggering Input (REX)

White/Orange  Remote Triggering Input (REX)

White/Black 

K (in) Keypad Active

White/Yellow  K (out)

Black 

Ground (outputs only)

Red 

V+ Filtered (outputs only)

5

- Yellow LED
+ Yellow LED

-

-

+

+

Green LED

Red LED

Green LED

Red LED

J2 – remove 

jumper for 

24V operation

TS1 Terminal Strip

SW1 Program 

Switch

V+ V- N/C C N/O

Fig. 5  9212i Circuit Board

Содержание 9212i

Страница 1: ...losure the selected outputs will energize for their programmed time The main relay if selected will energize for the same time period as the Master Code This feature is especially useful when controlling an electric locking device Keypress Feedback Audible Keypress The RCI keypads will acknowledge a keypress by momentarily illuminating the yellow LED This can be turned off through programming Keyp...

Страница 2: ...low LED Press 99 master code Flashes slowly 2 To change master code Press 1 new master code Flashes fast Repeat new master code Flashes slowly If main relay time must be changed substitute option 2 from Programming Options chart for step above 3 To add change second code Press 2 new user code Flashes fast Repeat new user code Flashes slowly 4 To add change third code Press 3 new user code Flashes ...

Страница 3: ... 1 0 14 Turn auto entry on Press 30 2 1 15 Turn auto entry off Press 30 2 0 16 Turn keypad active output on4 Press 43 0 99 17 Turn keypad active off Press 43 0 00 18 Erase keypad memory reset defaults Press 46 00000 00000 19 Energize selected output s with a user code5 Press 59 outputs i e 1 2 or 2 3 etc user location new code repeat code e g User 2 code of 4321 energize outputs 2 3 Press 59 23 02...

Страница 4: ...magnetic Lock Exit Button N O TS1 V V N C C N O Brown White Orange Fig 1 Basic access control w an electromagnetic lock Exit Button To Alarm Panel Closed Circuit Loop COM N O N O TS1 V V N C C N O Brown White Orange Fig 3 Shunting a Normally Closed N C Zone 4 2013 Rutherford controls www rutherfordcontrols com USA 2517 SQUADRON COURT SUITE 104 VIRGINIA BEACH VA 23453 Canada 210 shearson crescent c...

Страница 5: ...result if incorrectly inserted Fig 6 9212i Wiring Harness WARNING Plug this harness in with the leads facing down Permanent damage may result if incorrectly inserted Wire Color Wire Function White Not Used White Blue Output 3 50mA sink to ground White Red Output 2 50mA sink to ground Orange Output 4 panic 50mA sink to ground Brown Remote Triggering Input REX White Orange Remote Triggering Input RE...

Отзывы: