Instructions
1. Determine vertical centerline of door lock face and horizontal centerline of latch.
2. Transfer these centerlines to the door jamb.
3. Prepare door jamb as per drawing.
4. If required, install optional “no weld” mounting brackets per instructions (supplied with mounting brackets).
5. Attach insert (coil unit) to lip bracket with screws provided.
6. Attach faceplate to lip bracket with screws provided.
7. Connect wires from low-voltage side of transformer to terminal screws on strike. (Polarity is
not
observed.)
8. Install door strike in frame, attaching it with two screws provided.
Important:
For
mortise
locks, align ramps of lip bracket with deadlock trigger.
For
cylindrical
locks, align centerline of latch with centerline of strike.
RCI electric strike quality and reliability ensures excellent security for many years. RCI products are designed to
provide maximum holding power and to make tampering extremely difficult.
7104, 7304
Aluminum & Wood Frames
4104, 4304
Aluminum Frames
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A
1-1/4
1.250
31.75
B
4-7/8
4.875
123.8
C
3-3/8
3.375
85.7
D
7/8
.875
22.2
E
3/8
.375
9.5
F
1/8*
.125*
3.2*
G 1-11/16
1.687
42.85
Vertical
Vertical Vertical
X
C/L
C/L
C/L
Door
Door
Door
R
5/32
.156
4.0
K
4-1/8
4.125
104.7
M
12-24
N/A
N/A
Vertical Centerline
of Door
I N S T A L L A T I O N
Electric Strikes
TM
4 / 7 Series
*From face of mounting tab to face of frame
7105, 7305
Aluminum & Wood Frames
4105, 4305
Aluminum & Wood Frames
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A
1-1/8
1.125
28.58
B
5-7/8
5.875
149.0
C
3-3/8
3.375
85.7
D
7/8
.875
22.2
E
3/8
.375
9.5
F
1/8*
.125*
3.2*
G
1-11/16
1.687
42.85
Vertical Vertical Vertical
X
C/L
C/L
C/L
Door
Door
Door
R
5/32
.156
4.0
K
5-3/8
5.375
136.5
M
12-24
N/A
N/A
Vertical Centerline
of Door
IS4/7S
R01/02-JH