Power

Reader may be powered by the access panel Linear Power Supply 

or switch mode (provided the switching frequency is not 125kHz).

Voltage 

5 to 16VDC. 12VDC at the reader is recommended for best operation. 

Model

6005R

5395R

5355R

Current Draw

30-75mA

35-75mA

70-110mA

fleaPower™ Control Line

To reduce the average current required by the reader, connect the 

purple conductor to ground.  This will turn the LED off when inactive. 

Connection

Connection must be done in accordance with NFPA 70. Do not 

connect to a receptacle controlled by a switch.

Listings & Certifications

FCC compliance Statement: This device complies with part 15 of 

the FCC rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and 

(2) this device must accept any interference received, including 

interference that may cause undesired operation. 

Product can be used without license conditions or restrictions in 

all European Union countries, including Austria, Belgium, Den-

mark, Finland, France, Germany, Greece, Ireland, Luxembourg, the 

Netherlands, Portugal, Spain, Sweden, and the United Kingdom, 

as well as other non-EU countries, including Iceland, Norway, and 

Switzerland.

This device complies with Industry Canada licence-exempt RSS 

standard(s). 

Operation is subject to the following two conditions: 

(1) This device may not cause interference, and 

(2) This device must accept any interference, including interfer-

ence that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada 

applicables aux appareils radio exempts de licence.

L’exploitation est autorisée aux deux conditions suivantes:

(1) l’appareil ne doit pas produire de brouillage, et 

(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélec-

trique subi, même si le brouillage est susceptible d’en comprom-

ettre le fonctionnement.

IMPORTANT! Changes or modifications not expressly approved by 

Rutherford Controls Int’l Inc. (A DORMA Group Company) could 

void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with 

the limits for a Class A digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protec-

tion against harmful interference when the equipment is operated 

in a commercial environment. This equipment generates, uses, and 

can radiate radio frequency energy and, if not installed and used 

in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment 

in a residential area is likely to cause harmful interference in which 

case the user will be required to correct the interference at his own 

expense.

CAN ICES-3 (A)/NMB-3(A)

Troubleshooting

1. When the reader is first powered on it will beep 4-times and the 

Red LED will be on. 

2. Presenting a supported access credential will result in the reader 

beeping and the LED flashing once.
NOTE: The access panel controls LED functionality, such as 

switching the LED to Green.
If the reader does not recognize the card or fob (no beep, no LED 

flash) or exhibits short read range, please see the table below for 

possible causes and solutions.

Possible Cause

Corrective Action

Incorrect cabling

Verify gauge, connections and cabling 

length

Not enough power

12VDC recommended, 5VDC at reader is 

minimum

Incorrect card used Verify if card technology is supported
Reader/access 

panel not properly 

grounded

Earth ground needed-verify shield and 

reader ground are tied at access panel and 

connect to ground at one point

Supply generating 

interference

Verify switching frequency of power supply

Should any of the corrective actions mentioned above not im-

prove performance, disconnect the reader from the access panel 

and power it with a separate power supply or 9VDC battery and 

re-test card functionality. By powering the readers separately, most 

variables that may lead to reduced performance can be eliminated. 

Should the problem persist, please contact RCI directly. 

 

AWID is a trademark of Applied Wireless Identifications Group. 

HID is a registered trademarks of HID Global Coporation, an ASSA 

ABLOY company. Belden is a registered trademark of Belden 

Technologies, Inc.  All other trademarks are the property of their 

respective owners. RCI reserves the right to change specifications 

without notice.

  