Copyright
RCG Holdings Limited. All rights reserved
Page 35 of 63
i4 Flexi Installation Guide v2.1
Example 2
(Built-in External Wiegand reader) <-
set the Wiegand Input as “In Door Read Card” mode
Built-in RF Module Access Module: Follow the User Access Method (FP only, RF only, RF + FP, RF +
FP + PIN etc.)
Outside Wiegand Module: ONLY RF <-
enhance security and record all the IN/OUT event.
Example 3
(Without built-in RF module, External Wiegand reader only) <-
set the Wiegand Input as “Out Door
Read Card” mode
External Wiegand reader: Following the User Access Method (FP only, RF only, RF + FP, RF+ FP+
PIN etc.)
Summary
- If you connect with Built-in RF Module only, follow the User Access Method you have preset.
- If you connect external reader only, follow the User Access Method you have preset.
- If you connect with both Built-in RF Module and External Reader, the Built-in RF Module will
follow the User Access Method and external Reader must be card only.