background image

 

2

IMPORTANT NOTES 

 
Before connecting and using the amplifier, please read this instruction manual carefully and keep it on hand for 
future reference. The manual is to be considered an integral part of the product and must accompany the amplifier 
when it changes ownership as a reference for correct installation and use as well as for the safety precautions. 
RCF Spa. will not assume any responsibility for the incorrect installation and/or use of the product.

IANO

 

WARNING

: To prevent the risk of fire or electric shock, never expose this equipment to rain or humidity. 

 
 
SAFETY PRECAUTIONS 

 
1. All the precautions, in particular the safety ones, must be read with special attention, as they provide important 
information. 
2. The power supply voltage of this equipment is sufficiently high to involve a risk of electrocution; therefore, never 
install or connect the product with the power supply switched on. 
3. Before powering up the amplifier, make sure that all the connections have been made correctly and that the 
voltage of your power mains corresponds to the voltage shown on the rating plate on the unit; if it does not, please 
contact your RCF dealer. 
4. The metallic parts of the unit are earthed by means of the power cable. In the event that the current outlet used 
for power does not provide the earth connection, contact a qualified electrician to earth the equipment using the 
dedicated terminal. 
5. To protect the power cable from damage, make sure that it is positioned so that it cannot be stepped on or 
crushed by objects. 
6. To prevent the risk of electric shock, never open the amplifier. There are no parts on the inside that the user 
needs to access. 
7. Make sure that no objects or liquids can get into the amplifier, as this may cause a short circuit. 
8. Never attempt to carry out any operations, modifications, or repairs that are not expressly described in this 
manual.  
Contact your authorized service centre or qualified personnel should any of the following occur: 

the amplifier does not function (or functions in an anomalous way); 

the power supply cable has been damaged; 

objects or liquids have got into the unit; 

the amplifier has been subject to heavy impact. 

9. When the amplifier is not to be used for long periods of time, switch it off and disconnect the power cable. 
10. If the amplifier begins to emit any strange odours or smoke, switch it off immediately and disconnect the power 
supply cable. 
11. Do not connect this product to any equipment or accessories not specified. 
For suspended installation, only use the dedicated anchoring points and do not try to hang this product using 
HANDLES or  elements that are unsuitable or not specific for this purpose. 
Also check the suitability of the support surface to which the product is anchored (wall, ceiling, structure, etc.), and 
the components used for attachment (screw anchors, screws, brackets not supplied by RCF etc.), which must 
guarantee the security of the system/installation over time, also considering, for example, the mechanical vibrations 
normally generated by the transducer. 
To prevent the risk of falling equipment, do not stack multiple units of this product unless this possibility is specified 
in the instruction manual. 
12. RCF Spa. strongly recommends this product is installed by professional qualified installers (or specialised 
firms) who can ensure correct installation and certify it according to the regulations in force. 
The entire audio system must comply with the current standards and regulations regarding electrical systems. 
13. Supports and trolleys 
The equipment should only be used on trolleys or supports, where necessary, that are recommended by the 
manufacturer. The equipment/support/trolley assembly must be moved with extreme caution. Sudden stops, 
excessive pushing force and uneven floors may cause the assembly to overturn. 
14. There are numerous mechanical and electrical factors to be considered when installing a professional audio 
system (in addition to those which are strictly acoustic, such as sound pressure, angles of coverage, frequency 
response, etc.). 
15. Hearing loss 
Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure level that leads to hearing 
loss is different  from person to person and depends on the duration of exposure. To prevent potentially dangerous 
exposure to high levels of acoustic pressure, anyone who is exposed to these levels should use adequate 
protection devices. When a transducer capable of producing high sound levels is being used, it is therefore 
necessary to wear ear plugs or protective earphones. 
See the technical specifications in the instruction manual for the maximum sound pressure the loudspeaker is 
capable of producing 

Содержание TTS12-A

Страница 1: ...e design of our TT compact speakers with a clear idea in mind maximum high quality audio SPL in the smallest weight and size Thanks to our state of the art neodymium transducers premium quality analog...

Страница 2: ...t off and disconnect the power cable 10 If the amplifier begins to emit any strange odours or smoke switch it off immediately and disconnect the power supply cable 11 Do not connect this product to an...

Страница 3: ...power transformers mains cables lines that supply loudspeakers OPERATING PRECAUTIONS Do not obstruct the ventilation grilles of the unit Situate this product far from any heat sources and always ensur...

Страница 4: ...res transducers speaker systems and amplification and control electronics Our 50 plus years heritage in Audio combined with our state of the art research and development and manufacturing processes al...

Страница 5: ...f the system 180 10 AC POWERCON RECEPTACLE RCF TT series uses a POWERCON locking 3 pole AC mains Always use the specific power cord provided in the package 11 AC POWERCON LINK RECEPTACLE Use this rece...

Страница 6: ...rti 5 Qualora questo prodotto non sia utilizzato per lunghi periodi togliere la tensione dal cavo di alimentazione o scollegare l alimentatore esterno 6 Nel caso che dal prodotto provengano odori anom...

Страница 7: ...matori di grande di potenza cavi di rete linee che alimentano altoparlanti PRECAUZIONI D USO Non ostruire le griglie di ventilazione dell unit Collocare il prodotto lontano da fonti di calore e garant...

Страница 8: ...e audio abbinata ai nostri avanzati processi di ricerca e sviluppo nonch di produzione ci permette di integrare perfettamente tutti gli ingredienti che compongono il sistema TT INTENSIT La filosofia p...

Страница 9: ...ne alla sensibilit 2 dbu massimo guadagno in ingresso La sensibilit nella posizione centrale 4 dBu livello nominale richiesto per ottenere la massima potenza dagli amplificatori 9 PHASE 0 180 Questo p...

Страница 10: ...zo delle maniglie Le maniglie sono state progettate per il trasporto del diffusore non per la sua sospensione ATTENZIONE Assicurarsi sempre che la richiesta massima di corrente non superi la corrente...

Страница 11: ...Amplifier Panel Pannello Amplificatore 11...

Страница 12: ...se Switch Sensitivity Control ANALOG INPUT equalisation stereo crossover filtering fast limiter RMS limiter MECHANICAL Size 480 x 390 x 530 Weight 28 Kg RCF SpA Italy tel 39 0522 274 411 fax 39 0522 2...

Отзывы: