5
ENGLISH
THE REAR PANEL
1 - FEMALE XLR INPUTS (BAL/UNBAL)
The system accept XLR input connectors.
2 - MALE XLR SIGNAL OUTPUT
The output XLR connector provides a loop trough for speakers daisy
chaining. The balanced connector is connected in parallel and can be
used to send the audio signal to other amplified speakers, recorders
or supplementary amplifiers.
3 - SYSTEM SET UP ENCODER
Push the encoder to select a function (gain reduction, delay, preset).
Rotate the encoder to select a value or a preset.
4 - GAIN REDUCTION LED
Pushing the encoder once the gain reduction indicator lights green.
Then rotate the encoder to reduce the gain to the right level.
5 - DELAY LED
Pushing the encoder twice the delay indicator lights green. Then rotate the encoder to delay the speaker. The delay is expressed in meters.
6 - PRESET LED
Pushing the encoder three times the preset indicator lights green. Then rotate the encoder to load the right preset to the speaker.
7 - SYSTEM SET UP DISPLAY
Display the system setting values. In case of RDNet active connection a rotating segment will light up.
8 - RDNET LOCAL SETUP/BYPASS
When released the local setup is loaded and RDNet can only monitor the speaker. When switched the RDNet setup is loaded and bypass any speaker local
preset.
9 - RDNET RECALL LED
This orange LED lights up when the LOCAL SETUP/BYPASS switch is pressed. If connected, RDNet is taking control of the speaker the speaker.
10 - AC RDNET IN/OUT PLUG
The AC RDNET IN/OUT PLUG optional accessory is installed on the rear panel. In the picture the installed accessory is shown.
11 - LIMITER LED
The amplifier has a built in limiter circuit to prevent clipping of the amplifiers or overdriving the transducers. When the soft clipping circuit is active the LED
blinks RED. It is okay if the limit LED blinks occasionally. If the LED lights continuously, turn down the signal level.
12 - SIGNAL LED
The signal indicator lights green if there is audio signal present on the main input.
13 - STATUS LED
This yellow led is ON when the amplifier is in failure mode. In this case please contact the closest RCF service centre.
14 - POWER LED
This green led is ON when the speaker is connected to the main power supply.
15 - AC INPUT
Powercon locking 3-pole AC mains.
16 - AC OUTPUT
Powercon locking 3-pole AC mains output.
WARNING:
The Powercon connector is used to disconnect the system from the power supply network. It shall be easily accessible
after the instillation and during the use of the system.
WARNINGS