RCF TT25-SMA Скачать руководство пользователя страница 6

6

ENGLISH

INNOVATION

TT+ HIGH DEFINITION 
TOURING AND THEATRE

INTEGRATION

INTENSITY

TT25-SMA, 
PRECISION 
STAGE MONITOR

TT+ HIGH DEFINITION TOURING AND THEATRE

RCF TT+ represents another prominent chapter in the long history of RCF Sound Systems.
Whether a speaker system is designed for live sound or large concert situations as well as permanent 
installed theatre sound applications, the paying customer now expects a level of audio fidelity and 
intelligibility of such a standard unsurpassed by previous generations.
This requirement has fostered the need for Audio Professionals to be able to offer a range of 
speaker systems combined with dedicated Processing and Amplification Technologies that are 
superior in Acoustic Performance and Control Technology.
RCF TT+ offers ready to use solutions and tools in true active high definition speaker systems.

INNOVATION INTEGRATION INTENSITY
Innovation.

 Our research and engineering faculty can today offer innovative projects with 

finite control of each detail, from the loudspeaker voice coil wire to the highly efficient 
extended dynamic amplifier topology. There are many different ingredients that go into 
creating quality products and systems. These include computer aided simulation software 
to assist the understanding of transducer behaviour and amplifier operation and the 
relationship of dynamics and transient response. RCF utilise over thirty state of the art 
software packages to identify magnetic circuits, voice coil dynamics, suspension linearity, 
horn dispersion simulation, crossover filters, amplifier thermal behaviour etc.

Integration. 

RCF is one of only a few loudspeaker manufacturers worldwide who have 

the ability to completely design and manufactures transducers, speaker systems and 
amplification and control electronics. Our 50 plus years heritage in Audio combined with 
our state of the art research and development and manufacturing processes allows us to 
seamlessly integrate all the ingredients to design and build TT+.

Intensity. 

The design philosophy for the new TT+ series is based upon offering the sound 

engineer solutions and tools that are ready to use. Key factors are the ability to sustain very 
high power with highly efficient sound pressure levels. Intense sound levels are created with 
extremely high definition and extended dynamic range. Modern construction materials result 
in mechanical weight ratios that are light for practical flying and portability.

TT25-SMA, PRECISION STAGE MONITOR

The TT25-SMA is a full range, high power, precision stage monitor that sets a new standard in 
the touring and theatre sound reinforcement.
The coaxial transducer has been specifically designed for the application. The woofer provides 
large excursion and very light weight. The voice coil is a new 3.5” design, best compromise 
between power handling and low mass.
The compression driver features a new pure titanium dome. 

The input section provides:

- In/Out XLR connectors.
- System sensitivity control.
- Side to side coupling correction switch.
- 4 status LEDs.

TT25-SMA is a 2-way active system featuring:

- 15” neo woofer, 86 mm voice coil in a bass reflex configuration. 
- 1,5” exit, 64 mm voice coil neo compression driver.
- 60° x 60° conical, constant directivity horn.

The TT25-SMA amplifier section features:

- 750 watt switching power supply module.
- 500 watt low frequency digital amplifier module.
- 250 watt high frequency digital amplifier module.
- extra capacitor bus able to sustain the voltage for 100 ms burst signals.

PRODUCT 

INFORMATIONS

Содержание TT25-SMA

Страница 1: ...OWNER MANUAL TT25 SMA PRECISION STAGE MONITOR...

Страница 2: ......

Страница 3: ...3 ENGLISH ITALIANO LANGUAGE 4 9...

Страница 4: ...cribed in this manual Contact your authorized service centre or qualified personnel should any of the following occur The product does not function or functions in an anomalous way The power cable has...

Страница 5: ...e maximum sound pressure level IMPORTANT NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity...

Страница 6: ...de who have the ability to completely design and manufactures transducers speaker systems and amplification and control electronics Our 50 plus years heritage in Audio combined with our state of the a...

Страница 7: ...y if the limit LED blinks occasionally If the LED blinks frequently or lights continuously turn down the signal level The amplifier has a built in RMS limiter If the RMS limiter is active the LED ligh...

Страница 8: ...nect the power supply cable and the signal cable but before turning on the speaker make sure that the volume control is at the minimum level even on the mixer output It is important that the mixer is...

Страница 9: ...uda es candele accese deve essere posta sull apparecchio 4 Non eseguire sul prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di...

Страница 10: ...monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0dB usare solo cavi scherma...

Страница 11: ...icerca e sviluppo nonch di produzione ci permette di integrare perfettamente tutti gli ingredienti che compongono il sistema TT La filosofia progettuale della nuova serie TT si basa sulla volont di of...

Страница 12: ...ssima attenuazione alla sensibilit 2 dbu massimo guadagno in ingresso La sensibilit nella posizione centrale 4 dBu livello nominale richiesto per ottenere la massima potenza dagli amplificatori 4 LIMI...

Страница 13: ...rrente massima ammessa dai connettori POWERCON In caso di dubbio contattare il CENTRO ASSISTENZA RCF pi vicino 13 TERRA Il connettore di ingresso XLR segue il seguente standard AES PIN 1 TERRA GROUND...

Страница 14: ...endere il diffusore e alzare il controllo di livello a seconda delle necessit ATTENZIONE Assicurarsi sempre che la richiesta massima di corrente non superi la corrente massima ammessa dai connettori P...

Страница 15: ...PUTS Signal Input Output Power Input Output RDNet Input Output PHISICAL SPECIFICATIONS Dimensions w h d Net weight 50 20 000 Hz 131 dB 60 Conical 1 200 Hz 15 mid bass neo 86 mm voice coil 1 5 compress...

Страница 16: ...4 Int 44 870 626 3142 e mail info rcfaudio co uk RCF France tel 33 1 49 01 02 31 e mail france rcf it RCF Germany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info rcf...

Отзывы: