The XLR connectors use the following AES standard:
PIN 1 = GROUND (SHIELD)
PIN 2 = HOT (+)
PIN 3 = COLD (-)
CONNECTIONS
At this point you can connect the power supply cable and the signal cable, but before turning on the speaker make sure that the volume control is at the minimum
level (even on the mixer output). It is important that the mixer is already ON before turning on the speaker. This will avoid damage to the speakers and noisy “bumps”
due to turning on parts on the audio chain. It is a good practice to always turn on speakers at last and turn them off immediately after the show.
Now you can turn ON the speaker and adjust the volume control to a proper level.
BEFORE TURNING ON THE SPEAKER
TT22-A
230 Volt, 50 Hz SETUP :
FUSE VALUE T 3.15 A H 250 V
115 Volt, 60 Hz SETUP : FUSE VALUE T 6.3 A H 250 V
TT25-A
230 Volt, 50 Hz SETUP :
FUSE VALUE T 6.3 A H 250 V
115 Volt, 60 Hz SETUP : FUSE VALUE T 10 A H 250 V
VOLTAGE SETUP
(RESERVED TO THE RCF SERVICE CENTRE)
BAL. XLR
ENGLISH
5
A 35 MM socket for mounting the loudspeaker on a speaker stand is provided in the bottom of the cabinet. Always make sure that the pole mount that is used is able
to sustain the speaker weight with a proper safety factor.
TT+ speakers MUST be suspended only with approved rigging hardware. In any case always use at least 2 fly-track inserts.
TT22-A and TT25-A are equipped with 6 fly-tracks inserts. The inserts can be used in the following ways:
- single 3 points vertical installation
- single 4 points horizontal installation
- multiple 3 points vertical installation (max 3 in case of daisy chain)
- multiple 4 points horizontal installation (max 3 in case of daisy chain)
INSTALLATION
WARNING
:
Never suspend in DAISY CHAIN MODE more than 3 (three) cabinets.
WARNING
:
Never suspend TT+ speakers by there handles. Handles are intended for transportation, not for rigging.
WARNING
:
Always make sure that the maximum current requirement does not exceed the maximum admitted POWERCON current. In case of doubt call
the closest RCF SERVICE CENTRE.
2 x TT22A/TT25A in vertical daisy chain
TT22A/TT25A 4 points horizzontally suspended
TT22A and TT25A suspending accessory
AC DS-4x p.n. 13360030
Содержание TT22A