SAFETY PRECAUTIONS
1.

 All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2.

 Power supply from mains

a. 

The mains voltage is sufficiently high to involve a risk of electrocution; install and

 

connect this product before plugging it in.

b. 

Before powering up, make sure that all the connections have been made correctly

 

and the voltage of your mains corresponds to the voltage shown on the rating

 

plate on theunit, if not, please contact your RCF dealer.

c. 

The metallic parts of the unit are earthed through the power cable. An apparatus

 

with CLASS I construction shall be connected to a mains socket outlet with a

 

protective earthing connection.

d. 

Protect the power cable from damage; make sure it is positioned in a way that it

 

cannot be stepped on or crushed by objects.

e. 

To prevent the risk of electric shock, never open this product: there are no parts

 

inside that the user needs to access.

3.

 Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit.
This apparatus shall not be exposed to dripping or splashing. No objects filled with liquid, 
such as vases, shall be placed on this apparatus. No naked sources (such as lighted candles)
should be placed on this apparatus.

4.

 Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual.
Contact your authorized service centre or qualified personnel should any of the following 
occur:
- The product does not function (or functions in an anomalous way).
- The power cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.

5.

 If this product is not used for a long period, disconnect the power cable.

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately 

and disconnect the power cable.

7.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang 
this product by using elements that are unsuitable or not specific for this purpose. Also 
check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.), and the components used for attachment (screw anchors, screws, brackets 
not supplied by RCF etc.), which must guarantee the security of the system / installation 
over time, also considering, for example, the mechanical vibrations normally generated by 
transducers.
To prevent the risk of falling equipment, do not stack multiple units of this product unless 
this possibility is specified in the user manual.

8.

 RCF S.p.A. strongly recommends this product is only installed by professional 

qualified installers (or specialised firms) who can ensure correct installation 
and certify it according to the regulations in force.
The entire audio system must comply with the current standards and regulations 
regarding electrical systems.

9. Supports and trolleys
The equipment should be only used on trolleys or supports, where necessary, that are 
recommended by the manufacturer. The equipment / support / trolley assembly must be 

SAFETY

PRECAUTIONS

IMPORTANT

WARNING

Содержание ST 12-SMA

Страница 1: ...OWNER MANUAL PROFESSIONAL AUDIO STAGE MONITORING ST 12 SMA ST 15 SMA...

Страница 2: ...2 ENGLISH ITALIANO LANGUAGE 3 9...

Страница 3: ...g occur The product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this...

Страница 4: ...ith extreme caution Sudden stops excessive pushing force and uneven floors maycause the assembly to overturn 10 There are numerous mechanical and electrical factors to be considered when installinga p...

Страница 5: ...ducers in order to guarantee a better performance and great vocal reproduction All Compression drivers and woofers are precision built taking advantage of RCF s superior moulding assembly technologies...

Страница 6: ...MALE XLR SIGNAL OUTPUT The output XLR connector provides a loop trough for speakers daisy chaining VOLUME CONTROL Adjust the amplifier volume This control does not affect the Link Input Link output le...

Страница 7: ...can turn ON the speaker and adjust the volume control to a proper level The amplifiers are equipped with a microprocessor to control the DSP and the amplifier The correct switch on of the amplifier i...

Страница 8: ...ted The speaker switches to mute FLASHING INDICATION 1 or 2 Warning 3 or 4 Limitation from 5 to 8 Failure In case of failure the Ready green LED remains off Perform the checks listed below check if th...

Страница 9: ...eseguire sul prodotto interventi modifiche riparazioni se non quelle espressamentedescritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando...

Страница 10: ...ti tecnici del manuale d uso per conoscere le massime pressioni sonore che i monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasport...

Страница 11: ...la massima precisione grazie alle superiori tecnologie RCF di stampaggio lavorazione ed assemblaggio Risultati di eccellenza sono ottenuti grazie all esperienza il know how distribuito e standard pro...

Страница 12: ...ONTROLLO DI LIVELLO Varia il volume del diffusore FLAT BOOST Il pulsante imposta l equalizzazione Flat o Boost Quest ultima agisce come loudness per applicazioni musica quando il diffusore acustico vi...

Страница 13: ...Infatti buona regola che i diffusori amplificati e gli amplificatori in genere siano sempre le ultime apparecchiature ad essere accese dopo il montaggio e le prime ad essere spente alla fine dello sp...

Страница 14: ...diffusore viene posto nello stato di mute INDICAZIONI 1 o 2 Attenzione 3 o 4 Limitazione da 5 a 8 Guasto Nel caso di guasto il LED verde Power status rimane spento Nel caso si presenti un qualsiasi av...

Страница 15: ...P and Protection Circuits PHISICAL SPECIFICATIONS Dimensions w h d Weight Colour 45 20 kHz 129 dB 90 60 1 400 12 2 5 v c 1 1 4 v c 400 Watt 300 Watt 100 Watt 594 318 400 mm 18 Kg Black ST 12 SMA 45 20...

Страница 16: ...www rcf it RCF S p A Via Raffaello Sanzio 13 42124 Reggio Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it 10307471 RevA...

Отзывы: