IMPORTANT NOTES

SAFETY

PRECAUTIONS

IMPORTANT NOTES

Before connecting and using this microphone, please read this instruction 
manual carefully and keep it on hand for future reference. The manual is to 
be considered an integral part of this product and must accompany it when it 
changes ownership as a reference for correct installation and use as well as 
for the safety precautions.
 

RCF S.p.A. 

will not assume any responsibility for the incorrect installation 

and / or use of this product.

SAFETY AND OPERATING PRECAUTIONS

1. 

All the precautions, in particular the safety ones, must be read with special 

attention, as they provide important information. 
 

2. 

Make sure all connections have been made correctly before switching all 

devices on. 

 
3. 

Protect the microphone cable from damage.  

 

4. 

Do not put the microphone into water (or another liquid), do not throw it. 

 

5. 

Never attempt to carry out any operations, modifications or repairs. 

If the microphone does not work properly, contact your authorized service 
centre. 
 

6. 

Should the microphone emit any strange odour or even smoke, turn 

the PX 2100  / PX 4100 transmitter off immediately, then disconnect the 
microphone. 
 

7. RCF S.p.A. 

strongly recommends the sound system installation is only 

made by professional qualified installers (or specialised firms), who can certify 
it according to the regulations in force. 
The entire audio system must comply with the current standards and 
regulations regarding electrical systems. 
 

8. 

Do not aim the microphone to near loudspeakers, in order to avoid 

feedback. 
 

9. 

Hearing loss 

Exposure to high sound levels can cause permanent hearing loss. The acoustic 
pressure level that leads to hearing loss is different from person to person 
and depends on the duration of exposure. To prevent potentially dangerous 
exposure to high levels of acoustic pressure, anyone who is exposed to these 
levels should use adequate protection devices. When a transducer capable of 
producing high sound levels is being used, it is therefore necessary to wear 
ear plugs or protective earphones. 
 

10. 

Keep the microphone far from any excessive heat source. 

 

11. 

Do not use solvents, alcohol, benzene or other volatile substances for 

cleaning. Use a dry cloth.

Содержание HE 2006

Страница 1: ...USER MANUAL HE 2006 HEADSET MICROPHONE MICROFONO AD ARCHETTO ...

Страница 2: ......

Страница 3: ...3 INDEX INDICE ENGLISH SAFETY PRECAUTIONS DESCRIPTION CONNECTION SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO DATI TECNICI 4 5 5 6 8 9 9 10 ...

Страница 4: ...ervice centre 6 Should the microphone emit any strange odour or even smoke turn the PX 2100 PX 4100 transmitter off immediately then disconnect the microphone 7 RCF S p A strongly recommends the sound system installation is only made by professional qualified installers or specialised firms who can certify it according to the regulations in force The entire audio system must comply with the curren...

Страница 5: ...s It is suitable for lecturers singers dancers entertainers djs magicians instructors etc Suggested distance from the microphone capsule to the mouth is approximately 25 mm Polar pattern cardioid Connect directly the HE 2006 mini 4 pin XLR connector to the dedicated RCF PX 2100 PX 4100 input before turning the transmitter on PIN 1 ground 2 electret capsule power supply 3 not used 4 audio signal DE...

Страница 6: ... mV Pa 600 Ω 30 2 mA Type Polar pattern Sensitivity 1 kHz Impedance 1 kHz Consumption current Frequency response Polar pattern 0 180 90 270 60 120 30 150 330 210 300 240 20 10 10 20 0 50 100 500 FREQUENCY Hz RELATTIVE RESPONSE dB TK 5K 10K 20K 0 ...

Страница 7: ......

Страница 8: ...he dal microfono provengano stranamente odori anomali od addirittura fumo spegnere immediatamente il trasmettitore PX 2100 PX 4100 e poi scollegare il microfono 7 RCF S p A raccomanda vivamente che l installazione del sistema audio sia eseguita solamente da installatori professionali qualificati oppure da ditte specializzate in grado di farla correttamente e certificarla in accordo con le normativ...

Страница 9: ...ubbliche cantanti ballerini intrattenitori disc jockey prestigiatori istruttori ecc Distanza suggerita tra la capsula microfonica e la bocca circa 25 mm Diagramma polare direzionalità cardioide Collegare direttamente il connettore mini XLR a 4 poli del microfono HE 2006 all ingresso dedicato del trasmettitore RCF PX 2100 PX 4100 prima di accederlo PIN 1 massa 2 alimentazione per la capsula ad elet...

Страница 10: ...mV Pa 600 Ω 30 2 mA Tipo Diagramma polare Sensitività 1 kHz Impedenza 1 kHz Corrente assorbita Risposta in frequenza Diagramma polare 0 180 90 270 60 120 30 150 330 210 300 240 20 10 10 20 0 50 100 500 FREQUENZA Hz RISPOSTA RELATIVA dB TK 5K 10K 20K 0 ...

Страница 11: ......

Страница 12: ...5 1234 Int 44 870 626 3142 e mail info rcfaudio co uk RCF France tel 33 1 49 01 02 31 e mail france rcf it RCF Germany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info rcfaudio es RCF Belgium tel 32 0 3 3268104 e mail belgium rcf it RCF USA Inc tel 1 603 926 4604 e mail info rcf usa com ...

Отзывы: