RCF EVOX 12 Скачать руководство пользователя страница 4

4

ENGLISH

IMPORTANT

Before connecting and using this product, please read this instruction manual carefully and 
keep it on hand for future reference.
The manual is to be considered an integral part of this product and must accompany it when 
it changes ownership as a reference for correct installation and use as well as for the safety 
precautions.
RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of this 
product.

WARNING: 

To prevent the risk of fire or electric shock, never expose this product to rain or 

humidity.

SAFETY PRECAUTIONS
1.

 All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2.  POWER SUPPLY FROM MAINS

 

-

Appliance coupler or PowerCon Connector® is used to disconnect device from MAIN 
power. This device shall remain readily accessible after the installation

 

-

The mains voltage is sufficiently high to involve a risk of electrocution: never install or 
connect this product when its power cord is plugged in.

 

-

Before powering up, make sure that all the connections have been made correctly and the 
voltage of your mains corresponds to the voltage shown on the rating plate on the unit, if 
not, please contact your RCF dealer.

 

-

The metallic parts of the unit are earthed by means of the power cord.This is a Class I 
device and for its use it must be connected to a grounded power source.

 

-

Protect the power cord from damage. Make sure it is positioned in a way that it cannot be 
stepped on or crushed by objects.

 

-

To prevent the risk of electric shock, never open this product: there are no parts inside that 
the user needs to access.

3.

  Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit. This apparatus shall not be exposed to dripping or splashing. No objects filled with 
liquid (such as vases) and no naked sources (such as lit candles) should be placed on this 
apparatus.

4.

 Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual. 
Contact your authorized service centre or qualified personnel should any of the following 
occur:

 - The product does not function (or functions in an anomalous way).
 - The power cord has been damaged.
 - Objects or liquids are inside the product.
 - The product has been subject to a heavy impact.

5. 

If this product is not used for a long period, disconnect its power cord.

6. 

If this product begins emitting any strange odours or smoke, switch it off immediately and 

disconnect its power cord.

7.

 Do not connect this product to any equipment or accessories not foreseen.

Do not try to hang this product by using elements that are unsuitable or not specific for this 
purpose.
To prevent the risk of falling equipment, do not stack multiple units of this product unless this 
possibility is specified in the user manual.

IMPORTANT

WARNING

SAFETY PRECAUTIONS

Содержание EVOX 12

Страница 1: ...OWNER MANUAL MANUALE D USO EVOX 12 PROFESSIONAL ACTIVE TWO WAY ARRAY ...

Страница 2: ......

Страница 3: ...ON SUBWOOFER REAR PANEL AND CONNECTIONS SPECIFICATIONS EVOX 5 SIZE EVOX 8 SIZE ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE INSTALLAZIONE PANNELLO POSTERIORE DEL SUBWOOFER E CONNESSIONI DATI TECNICI DIMENSIONI EVOX 5 DIMENSIONI EVOX 8 4 6 7 8 11 12 13 14 16 17 18 21 22 23 ...

Страница 4: ...nd for its use it must be connected to a grounded power source Protect the power cord from damage Make sure it is positioned in a way that it cannot be stepped on or crushed by objects To prevent the risk of electric shock never open this product there are no parts inside that the user needs to access 3 Make sure that no objects or liquids can get into this product as this may cause a short circui...

Страница 5: ...ure anyone who is exposed to these levels should use adequate protection devices When a transducer capable of producing high sound levels is being used it is therefore necessary to wear ear plugs or protective earphones See the manual technical specifications to know the maximum sound pressure level 11 Situate this product far from any heat sources and always ensure adequate air circulation around...

Страница 6: ...ltra compact full range 4 driver can handle extremely high sound pressure levels and power The high excursion woofers are able to extend to the lowest frequencies and offer a quick and precise response up to the crossover point Specific attention has been dedicated to mid low frequencies as well CONTROLLED DIRECTIVITY PATTERN EVOX array design features a constant horizontal directivity coverage of...

Страница 7: ...io input 1 4 TRS jack 2 Balanced audio input female XLR connector 3 Balanced parallel audio output male XLR connector This output is linked in parallel with the audio input and is useful to connect another amplifier Female XLR connector PUSH 2 1 3 Male XLR connector 2 1 3 PUSH 2 1 3 2 1 3 MAX VOLUME LIMITER FLAT BOOST LINE MIC SIGNAL STATUS BALANCED INPUT LINK INPUT SENSITIVITY 2 3 4 7 8 9 6 5 1 X...

Страница 8: ...t low volume levels 7 LIMITER LED The internal amplifier has a limiter circuit to prevent clipping and overdriving transducers It blinks when the signal level reaches the clipping point causing the limiter intervention If it is steady lit the input signal level is excessive and should be reduced 8 SIGNAL LED When lit it indicates the signal presence at the audio input 9 STATUS LED When blinking it...

Страница 9: ...er cord check if the mains corresponds to the voltage indicated on the rating plate on the unit if not please contact your RCF dealer Connect the power cord only to a mains socket outlet with a protective earthing connection When replacing the fuse refer to the silk screen indications WARNING the VDE Power Connector is used to disconnect the system from the power supply network It shall be easily ...

Страница 10: ... DSP Amplifier power low frequencies 1000 W peak Amplifier power high frequencies 400 W peak Input sensitivity LINE 4 dBu Crossover frequency 180 Hz Protections thermal RMS Limiter software limiter Cooling convective Operating voltage 115 230 V 50 60 Hz Inrush current 10 1 A According to EN 55013 1 2009 SUBWOOFER PHYSICAL Height 2220 mm 87 4 Width 410 mm 16 14 Depth 560 mm 22 05 Net weight 36 4 kg...

Страница 11: ...11 ENGLISH EVOX 12 SIZE ...

Страница 12: ...talliche dell apparecchio sono collegate a terra tramite il cavo di alimentazione Questo è un apparato di Classe I e per il suo funzionamento deve essere connesso ad un presa di alimentazione provvista del conduttore di terra di protezione Accertarsi che il cavo di alimentazione dell apparecchio non possa essere calpestato o schiacciato da oggetti al fine di salvaguardarne la perfetta integrità Pe...

Страница 13: ...zi delle adeguate protezioni quando si fa funzionare un trasduttore in grado di produrre elevati livelli sonori è necessario indossare dei tappi per orecchie o delle cuffie protettive Consultare i dati tecnici istruzioni per conoscere le massime pressioni sonore che i diffusori acustici sono in grado di produrre 11 Collocare il prodotto lontano da fonti di calore e garantire la circolazione dell a...

Страница 14: ...tto driver full range da 4 può essere impiegato con livelli estremamente elevati di pressione sonora e potenza I woofer ad alta escursione sono in grado di riprodurre le frequenze più basse e di offrire una risposta rapida e precisa fino al punto di crossover un attenzione particolare è stata data anche alle frequenze medio basse DISPERSIONE CON DIRETTIVITÀ CONTROLLATA La disposizione in linea dei...

Страница 15: ...ip segnale 1 Ingresso audio bilanciato connettore jack 1 4 TRS 2 Ingresso audio bilanciato connettore XLR femmina 3 Uscita audio bilanciata connettore XLR maschio Questa uscita è collegata in parallelo con l ingresso audio ed è utile per la connessione di un altro amplificatore Connettore XLR f PUSH 2 1 3 Connettore XLR m 2 1 3 PUSH 2 1 3 2 1 3 MAX VOLUME LIMITER FLAT BOOST LINE MIC SIGNAL STATUS ...

Страница 16: ...basso volume 7 LED LIMITER L amplificatore interno ha un limitatore per evitare la saturazione del segnale ed il sovraccarico dei trasduttori Il LED lampeggia quando il livello del segnale raggiunge il massimo prima della saturazione causando l intervento del limitatore nel caso il LED sia costantemente acceso il livello del segnale d ingresso è eccessivo ed andrebbe diminuito 8 LED SIGNAL Quando ...

Страница 17: ... cavo d alimentazione assicurarsi che tutte le connessioni siano corrette e che la tensione di rete corrisponda quella di targa dell apparecchio in caso contrario rivolgersi ad un rivenditore RCF Collegare il cavo d alimentazione solo ad una presa di rete avente la messa a terra Nel caso di sostituzione del fusibile riferirsi ai dati di targa serigrafati ATTENZIONE il connettore VDE è il dispositi...

Страница 18: ...ficatore frequenze basse 1000 W picco Potenza amplificatore frequenze alte 400 W picco Sensibilità ingresso LINE 4 dBu Frequenza di crossover 180 Hz Protezioni termica RMS Limiter soft limiter Raffreddamento convezione Tensione di funzionamento 115 230 V 50 60 Hz Corrente di accensione 10 1 A in accordo a EN 55013 1 2009 FISICI DEL SUBWOOFER Altezza 2220 mm 87 4 Larghezza 410 mm 16 14 Profondità 5...

Страница 19: ...19 ITALIANO DATI TECNICI DIMENSIONI EVOX 12 ...

Страница 20: ...www rcf it RCF S p A Via Raffaello Sanzio 13 42124 Reggio Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it 10307492 RevB ...

Отзывы: