PAGE
282-C
TRK9, TRK90, TRKI2, TRKI20
Replacement Parts (Continued)
STOCK
No.
DESCRIPTION
7,600 VOLT TE LEV ISIO N POWER
UNIT
KK-7A in TRK-9 (60 cycle)
KK-7E in TRK-9 (50 cycle)
KK-7 in TRK-12 (60 cycle)
KK-7D in TRK-12 (50 cycle)
KK-7H in TRK-90 (60 cycle)
KK-7F in TRK-120 (60 cycle)
KK-7J in TRK-120 (50 cycle)
34600
34601
33246
33605
33016
33288
33018
34331
18388
32400
33023
14854
32940
35887
30314
33037
33971
33002
10907
34527
33015
32937
33244
33166
35897
33501
33502
33593
33554
33024
18007
33245
31251
12143
32909
32939
32938
34302
9861
34526
35888
Bushing— Porcelain bushing and spring................
Cable— Insulated connector complete with cable
for Kinescope (
2
nd anode)...................................
Capacitor— 0.03 mid.. 7,500 volt (C113. C114)
Capacitor— 0.1 mfd., 7,500 volt (C
121
, C122)
(Used in 50 cycle model only)..........................
Capacitor— 0.25 mfd., 600 volt (C120, C128)
Capacitor— 20 mfd., 450 volt ( C l i i , C 1 1 2 )..
Capacitor— 80-10 mfd., 400 volt (C110, C109;
C118, C 119).............................................................
Choke— Filter choke ( L 4 9 ).......................................
Choke— Filter choke (L 50) (Used in TRK-9,
TRK-12, T R K -120,‘50 cycle)....... ....................
Choke— Filter choke (L 50) (Used in TRK-90
and TRK-120, 60 cycle o n ly )........................ . .
Clip— Plate connector for 2V3G Radiotron. . . . .
Control— Focus control, 400,000 ohms . (R129)
(Used in first production TRK-9, TRK-12,
and in T R K -90).....................................................
Control— Focus control, 400,000 ohms (R129)
(Used in second production TRK-9, TRK-12,
and in T R K -120)................................................
Coupling— Flexible bronze coupling.......................
Fuse— 3 ampere, 250 volt.'....................................
Fuse
— 4
ampere glass type fuse................................
Insulator— Stand-off insulator only— less hardware
Knob— Focus control- knob.......................................
Plug— 2-prong male connector for A.C. power
cord ( X 2 2 ) ................................................................
Plug— 2-prong male plug for Kinescope grid-
cathode cable ( X 4 ) ................................................
Resistor— 60 ohms, 10 watt (R 1 6 5 ).....................
Resistor— 330.000 ohms, 1W (1,000V .) (R126.
R130) ............................................................... ..
Resistor— 470,000 ohms. 1W (1,000V .) (R127,
R137, R166) (R128 in TRK-9, TRK-12.
TRK-90, and TRK-120 with D.C. Restorer).
Resistor— 560,000
ohms,
1
watt
(1,000V .)
(R128 in TRK-90 and TRK-120 without D.C.
Restorer) ..................................................................
Resistor— 820,000 ohms. 1W (1,000V .) (R131,
R132. R133, R134, R135, R 1 3 6 )......... .......
Shaft— Bakelite shaft for focus control...................
Socket— Ceramic octal base socket and retaining
ring for high voltage rectifier............................ .
Socket— Kinescope socket, less cable ( X l l ) .........
Socket— Octal base 5T4 or 5U4G rectifier, or
television power supply socket ( X 1 3 ) . . . . . . . .
Socket—
6
-prong television power supply socket
(X 1 5 ) .......................................................................
Support— Rectifier socket, plate, and stand-off in
sulator assembly. .............. .......................... .. S •,.
Transformer— Filament power transformer .(T 7),
105-125 volts, 50-60 cycle.
Transformer— Low voltage power transformer
(T 5), 105-125 volt, 60 cycle (Used in 60
cycle models o nly)................................................
,
Transformer—-Low voltage power transformer
(T
8
), -105-125 volts, 50 'cycle (Used in 50
cycle models only). . . . .. . .
I
.... . . I . . . .
Transformer— High, voltage power transformer
(T
6
), 105-125 volts, 60 cycle (Used ,iij 60
cycle models only). . . .
4
. ......... v . . ’. I . / . . . . . '
Transformer— High voltage power transformer
(T 9), 105-125 volts, 50 cycle (Used in TRK-
9, 60 cycle and TRK-12, 50 cycle o n ly )..............
Transformer— High voltage power transformer
(T 9), 105-125 volts, 50 cycle (Used in TRK-
120. 50 cycle o nly)..................
■
31825
11469
11234
31275
31567
31539
31556
31557
SPEAKER ASSEMBLY .
RL-70F-5
Cap— Cone center dust cap......... .........................
Coil— Hum neutralizing coil (L 2 1 ). . . ................
Coil— Speaker field coil ( L 1 7 )................ ..
Cone— Speaker cone assembly (L 1 8 ) ..................
Plug— 3-prong male feed back cable plug (X 8 ). .
Plug— 5-prong speaker plug ( X 1 0 ) . . . ' . ..............
Speaker— Speaker complete (R L -70F -5)...........
Transformer— Speaker output transformer ( T l ) . .
39872
33597
32897
4573
33363
33002
31456
32815
33019
33643
35894
38305
35890
35893
35891
35896
35392
35892
35895
33442
33329
35889
32083
33074
33076
33282
33468
33470
33471
33472
33469
11891
31589
31458
31457
33075
33225
4577
33244
33166
32816
12493
4574
16836
31542
31287
31306
4560
35032
33517
14270
M ISCELLANEOUS ASSEM BLIES
30330
33362
31358
33676
33480
Button— Station selector push button.....................
Cable— 17 J-inch shielded audio lead with> plugs
(X 6. X 18) (Model TRK-9 and TRK-90 only)
Cable— 38-inch shielded audio lead with plugs
(Model TRK-12 and TRK-120 only) (X6,
X 18) ....... ..................................................................
33384
31622
31478
9857
DESCRIPTION
Cable— Kinescope cable and socket (TRK-12 and
TRK-120 only).........................................................
Cable— Kinescope cable and socket (TRK-9 and
TRK-90 only)....................................................... ..
Cable— Low capacity Kinescope grid cable (TRK-
12 and TRK-120 o nly)................ . . . ' ............. ..
Cable— Low capacity Kinescope grid cable (TRK-
9 and TRK-90 o n ly )......... .'................................
Cable— Television power supply cable*...................
Cap— Blue pilot lamp "Bulls Eye"................
Clamp— Deflecting yoke clamp assembly..............
Connector— 2-prong female connector for power
supply circuit ( X 2 3 ) ..................
^....
Connector— 2-prong female connector, used on
interlock cable’ ( X 2 1 ) ..............................................
Coupling— Flexible bronze coupling.......................
Cover— Eight protective covers for. push button
markers .................................................................. ..
Cushion— Kinescope masking cushion (TRK-12
and TRK-120 only)..............................................
Cushion— Kinescope masking cushion (TRK-9
and TRK-90 o n ly ). . . . . . . . . , , . . . . . . . ' .
Cushion— Television chassis mounting cushion
with screw, spacer and washer (sufficient for
one chassis)..'................ ............................... ...........
Decalcomania— "1-2-3-4-5" decal (TRK-12 and
TRK-120) ............................... ...............................
Decalcomania— "1-2-3-4-5’* decal (TRK-9 and
TRK-90) .................................................... .............
Decalcomania— "Contrast-Brightness” decal.........
Decalcomania— "Fine Tuning" decal.....................
Decalcomania— "Horizontal and Vertical Holding”
decal
......................... ...............................................
Decalcomania— "Power-Volume,
tone,
tuning,
range" decal..........................................‘................
Decalcomania— "RCA Victor" decal.....................
Decalcomania— "Station selector” decal.......
D ec alcomania— “ Viet rola- R adio-T el e vision' I decal
Dial— Three-band glass dial scale.........................
Escutcheon— Dial escutcheon less buttons, but
ton shaft and dial scale (TRK-9 and TRK-12)
Escutcheon— Dial escutcheon less buttons, button
shaft and dial scale (TRK-90 and TRK-120)
Frame-?—Dial frame with screen less pointer, car
riage and rod. . . *...................................................
Glass 62 'by
84
inch safety protective glass
(TRK-9 and TRK-90 o n l y ) . . . .........................
Glass
— 84
by 112 inch safety protective glass
(TRK-12 and TRK-120 only)................ .. . .
Hinge— Piano type lid hinge and screws................
Knob— Radio tuning,' volume or range selector
knob ........................ ••• Q . . • • • • ... . . . ... . , . . ...
V
Knob— Television "Contrast,” ' "Hor. hold” or
"Fine Tuning” k n o b . . . . ......... ...........................
Knob— Television "Brightness” or “Vert, hold”
knob ........................................
.
Knob— Television "Station selector” knob............
Knob— ‘ ‘ V ictrola- Radio-T elevision- Fidelity..... selec
tion" knob........... ............
^ -• j
Lamp— 6.3 V. pilot lamp, Mazda No. 4 4 . . . . . . .
Marker— Complete set of call letter markers. . . .
Marker— "Dial Tuning” push button marker. . .
Marker— "Victrola” push button marker..............
Mirror— 2 0 , by 14* in. viewing mirror................
Nut— Speed nut for mounting high frequency
c o il, a
s
s
e
m
b
l
i
e
s
|
rj
Plug— 2-prong male plug for power supply cir
cuit (X 2 4 ).................... ...............H
Plug— 2-prong male j>lug, used on interlock cable
( X
2 2
) ..................................
'./* fg
Plug— 2-prong male plug for Kinescope grid- .
cathode cable ( X 4 ) .....................| ........................
Plug— 4-prong male plug for deflecting yoke cable
(X
2
) ...........
m
............................
Plug— 5-prong female speaker cable plug ( X 9 ) ..
Plug—
6
-prong male plug for Television chassis
power supply cable ( X 1 4 ) . . . ..............-............
Plug—
8
-prong male plug for Television chassis
power supply cable ( X 1 2 ) ................................ ..
Pointer— Station selector .pointer with carriage..
Rod— Dial frame pointer slide rod............................
Screen— Dial .frame diffusing screen with r iv ets..
Screw— £-20 by 1£ in. long, machine screw,
washer and lockwasher for chassis mounting
(1 2
required)
. 1
............*..............
Shaft— Push button pivot shaft . ..............................
Sleeve— Bell mouth sleeve for screw-driver ad
justments (TRK-9 and TRK-90 o n ly );...........
Spring— Knob spring for Stock Nos. 33468,
33471, 33472, 33469 knobs........................... ..
Spring— Knob spring for Stock Nos. 33470, knob
Switch— Interlock switch with leads (TRK-9 and
TRK-12)
.....................................................
Switch— Interlock switch and cover (TRK-90 and
TRK-120) ................................................................
Support— Left hand lid support................ .............
Support— Right hand lid support............................
Yoke— Deflecting yoke complete with cable and
4-prong plug (L43, L44, R 6 2 ).........................
Содержание Victor TRK-12
Страница 5: ...PAGE 2 5 S C ...
Страница 8: ...PAGE 2S8 C ...
Страница 9: ...PAGE 2 5 9 C ...
Страница 10: ......
Страница 11: ...Figure 10 Schematic Diagram TRK 90 and TRK 120 W ithout D C Restorer ...
Страница 15: ...Figure 14 V ideo Chassis Wiring TRK 90 and TRK 120 Without D C Restorer ...
Страница 22: ...PAGE 2 7 5 C ...