S. O. 765244 

INSTALLATION 

Subject: 

Date     

Jan. 14,   1936 

AND 

 

Pickup Head 

 

Number   

3.180-B 

SERVICE DIVISION 

 Model 

D 22-1 

Classification 

Part Number 11481 

 

 

 

Instructions 

                         RCA Manufacturing Company, Inc                          

and 

 

                                                 NATIONAL OFFICE                                               

Information 

Camden,  N. J. 

 

 

 

 

INSTRUCTIONS AND INFORMATION 

 
 
 
 

 

Trouble may be experienced with the D22-1 pickup head due to instability of the 
armature centering adjustment. Improvements have been made in recent production 
to minimize this condition by decreasing the diameter of the centering spring and 
making a more substantial attachment of the same spring to the pickup armature. 
These later heads should give no trouble, however, if your observations are to the 
contrary a report should be promptly made. 

 

The improved head may be identified by inspection of the armature and centering 
spring arrangement.   The spring is looped around the armature and its end hooked 
around its straight portion. 

 

When unstable adjustment is obtained with the original type of pickup the complete 
head should be replaced with one of the later improved type.   The original heads 
should be accumulated for return to Camden on a Field Removal Tag for credit. 

 

 
 
 

W.J. Zaun 

Installation and Service 
 

Camden, New Jersey. 

 

Содержание D 22-1

Страница 1: ...the audio expander stage Improvements have recently been effected in the manner of supporting the 6L7 elements so that the tendency to howl is eliminated D 22 1 instruments and tubes of the 6L7 type received lately should therefore be free from howling tendencies The howl produced by the origina1 type of 6L7 is usually at a frequency of about 2000 cycles Any howl experienced with the later type wi...

Страница 2: ...being made on turntable wow spindle eccentricity microphonic howl all tubes cabinet finish pick up heads and audio quality at low gain Instruments coming through distributors should be again thoroughly tested to assure that our tests are taking effect Troubles should be promptly reported giving the usual complete information on serial number code number classification and description of fault Cabi...

Страница 3: ...spring and making a more substantial attachment of the same spring to the pickup armature These later heads should give no trouble however if your observations are to the contrary a report should be promptly made The improved head may be identified by inspection of the armature and centering spring arrangement The spring is looped around the armature and its end hooked around its straight portion ...

Страница 4: ... care should be taken however that the main gear of the automatic mechanism is not damaged during adjustment of one of those clamping screws In making the adjustment use either a constant frequency record at approximately 1 000 cycles or a musical selection having sustained notes in which the wow can be noticed After having determined that wows are present the two clamping screws should be loosene...

Страница 5: ...ntable 180 with reference to its original position on the spindle will help decrease the amount of vertical turntable wobble All of the above tests should be made with only one recordon the turntable since record slippage if two records were used would give misleading results The bearings of the motor should be checked to see that they are properly lubricated W J Zaun Installation and Service Camd...

Отзывы: