UNC500 TCP/IP Connection
The master controller in some installations may not be directly connected to the PC and
may be linked by the local Ethernet. The system supports a static IP address only
[
default address is 192.168.168.125
]. To change the IP address of the unit you can either
use IPLocator [
a utility program provided by RBH
] or Telnet.
PC to UNC500 Connection - LAN
*** For ULC-S319-05 III compliance, all wiring into the chassis mount panel’s cabinet must enter
through metal conduit. Also be sure to mount the panel in a protected area.
*** For ULC-S319-05 III compliance, the rack mount panel’s housing must have external tamper
switch to detect the housing’s removal from the rack. Also be sure to mount rack in a protected
area.