background image

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SYDNEY  |  MELBOURNE  |  BRISBANE  |  PERTH  |  AUCKLAND

Australia

   1300 788 778   www.rba.com.au   |

   New Zealand

   0800 722 111  www.rbagroup.co.nz

3 of 4

915 (760 Juni

or)

4

140

3

2

6

1

200

200

7

5

9mm Floor Anchoring Holes 

100mm DIA. Waste & Water Supply

Floor Anchors (By Others)

Stainless Steel Access Panel

Vandal Resistant Fasteners

4

(Anchors By Others)

Opening

7

6

5

3

2

8

8

Bubbler

1

280

Problem

Probable Cause

Solution

No flow or low volume

Water turned off.
Inlet strainer blocked.

Turn on.
Remove and clean.

Water flows continuously

Cartridge blocked with dirt or cartridge 
damaged

Remove and clean.
Replace the cartridge

Leak from body

Loose cap or cartridge damaged

Tighten cartridge cap.
Replace the cartridge

Short or long flow stream

Low or high pressure

Rectify supply pressure as per hydraulic 
requirements

Short or long flow stream

Cartridge adjustment required

Remove button, adjust white screw in 
cartridge clockwise to reduce, or counter 
clockwise to increase.

Troubleshooting

RBA Code No.

Description

RBA8900-999-002

Replacement cartridge

Spare Parts

Содержание RBA8903 Series

Страница 1: ...AIN RBA8903 151 JUNIOR HEIGHT VERSION As improvements in the design and performance of RBA products are continuous specifications may be subject to change without notice The illustrations and descriptions herein are applicable to production as of the date of this Installation Instructions Sheet Revised 07 22 2022 by RBA Group II Model RBA8903 102 0722 RBA8903 102 Free Standing Drinking Fountain RB...

Страница 2: ...3500 2 local authority and statutory requirements and as per these installation instructions 1 Water and waste supply should be provided through the floor in the locations shown on the drawing 2 Water should be able to be isolated from inside the unit and be flushed prior to connections 3 40mm trap on waste by others Installation 1 Remove the access panel from the unit using the security bit provi...

Страница 3: ...ution No flow or low volume Water turned off Inlet strainer blocked Turn on Remove and clean Water flows continuously Cartridge blocked with dirt or cartridge damaged Remove and clean Replace the cartridge Leak from body Loose cap or cartridge damaged Tighten cartridge cap Replace the cartridge Short or long flow stream Low or high pressure Rectify supply pressure as per hydraulic requirements Sho...

Страница 4: ...ersons in a fit for purpose application to suitable materials using suitable fixings and comply with any relevant codes It should be inspected periodically for signs of wear and tear that may affect performance or safety Dimensions are subject to manufacturer s tolerance of 10mm Rough in should be completed with each fixture Important Installation Instructions are subject to change without notice ...

Отзывы: