SPARE PARTS
PROBLEM
POSSIBLE CAUSES
SOLUTION
No flow or low volume
Water turned off.
Inlet strainer blocked.
Turn on.
Remove and clean.
Water flows continuously
Cartridge blocked with
dirt or cartridge damaged
Remove and clean.
Replace the cartridge*
Leak under knob
Loose screws or cartridge
damaged
Tighten brass screw
under white flow
adjustment screw.
Replace the cartridge*
Short or long flow stream
Low or high pressure
Rectify supply pressure
as per hydraulic
requirements
Short or long flow stream
Cartridge adjustment
required
Remove button, adjust
white screw in cartridge
clockwise to reduce,
or counter clockwise to
increase.
*Replacement Cartridge Model RBA8900-999-002
TROUBLE SHOOTING
RBA Code Number
Part Description
RBA8900-999-002
Replacement cartridge
WM-022317
Global
-
Mark
.
com
.
au®
Q
ua
lit
y M
ana
gement
.
ISO
90
01
INSTALLATION INSTRUCTIONS
RBA8903-102 FREE STANDING DRINKING FOUNTAIN
RBA8903-151 JUNIOR HEIGHT VERSION
As improvements in the design and performance of RBA products are continuous, specifications may be subject to change without notice.
The illustrations and descriptions herein are applicable to production as of the date of this Installation Instructions Sheet. Revised 07/22 © 2022 by RBA Group II/Model RBA8903-102/0722
RBA8903-102
Free Standing Drinking Fountain
RBA8903-151
Free Standing Drinking Fountain, Junior Height
MODELS
RBA8903-SERIES