background image

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SYDNEY       

|

       MELBOURNE       

|       

BRISBANE       

|       

PERTH       

|       

AUCKLAND

Australia

 

1300 788 778  |  www.rba.com.au                                        

New Zealand

 0800 722 111  |  www.rbagroup.co.nz

SYDNEY       

|

       MELBOURNE       

|       

BRISBANE       

|       

PERTH       

|       

AUCKLAND

Australia

 

1300 788 778  |  www.rba.com.au                                        

New Zealand

 0800 722 111  |  www.rbagroup.co.nz

SYDNEY  

|

  MELBOURNE  

|  

BRISBANE  

|  

PERTH  

|  

AUCKLAND

Australia   

1300 788 778   www.rba.com.au   

|   

New Zealand   

0800 722 111  www.rbagroup.co.nz

2

 

Components

“P” Trap Stainless Steel Pan  

“S” Trap converter

Security bit

Pre-installation

Installation should be in accordance with local authority and statutory requirements, 
and as per these installation instructions.

Pan is “wall faced” and should preferably be fixed to a masonry wall with
suitable wall anchors provided by others. Supplied with “S” trap converter to
allow either “S” or “P” configuration.

Flushing device should be –
 

 

 

Fowler Tasman Mk 2 (or Stylus Symphony) cistern

 

 

 

Caroma Invisi II (Inceiling mount recommended)

 

 

 

Sloan Dual Flush Valve

Installation

1.   If not pre-formed, make sufficient penetrations through the wall, as
 

determined from the drawing, to allow the 100 mm waste pipe, 50 mm

 

flush pipe, and, if necessary, 12 mm fixing rods to pass through. If front

 

fixed, suitable wall anchors supplied by others.

2.   Determine floor mounting location by mocking up.

3.   Fit a 100 mm pan collar to the outlet with sufficient 100 mm pipe to extend
 

through the wall. (Alternately the waste and flush pipes may be preplumbed

 

and the pan pushed onto the pipework.) If “S” trap configuration

 

is required, location of floor penetration should be centred 220mm from

 

finished wall.

4.   Similarly fit a 50 mm keeseal to the pan inlet with sufficient pipe, as
 

provided by the cistern manufacturer, to extend through the wall.

5.   Push the pan into position and secure the pan to the wall & floor (fixings by
 others).

6.   Make the necessary connections to the waste, and install the cistern and
 

connect according to the manufacturers instructions.

7.   Check for leaks and correct flush volumes, 6 litres full flush and 3 litres half
 flush.

Содержание RBA8851-137-PP

Страница 1: ...NS SYDNEY MELBOURNE BRISBANE PERTH AUCKLAND Australia 1300 788 778 www rba com au New Zealand 0800 722 111 www rbagroup co nz 1 Bariatric Toilet RBA8851 137 PP RBA8851 137 SS Date 28 09 17 Model Bariatric Toilet Supercedes all previous Lic WMKA 00291 ...

Страница 2: ...gh the wall as determined from the drawing to allow the 100 mm waste pipe 50 mm flush pipe and if necessary 12 mm fixing rods to pass through If front fixed suitable wall anchors supplied by others 2 Determine floor mounting location by mocking up 3 Fit a 100 mm pan collar to the outlet with sufficient 100 mm pipe to extend through the wall Alternately the waste and flush pipes may be preplumbed a...

Страница 3: ...om au New Zealand 0800 722 111 www rbagroup co nz 3 Installation Front Fixed Shown 1 Access Panels 2 Optional RBA8186 853 Big John Hinged Seat Rated 545kg 3 55mm ID Flushing Inlet Keyseal By Others 4 Wall Anchors and Anchoring Hardware By Others 5 100mm OD Waste Outlet 6 Mounting Slots Ø15mm x 38mm View From Rear of Fixture 6 ...

Страница 4: ... mild non abrasive detergent e g Dawn in cold or ambient temperature water using a soft non abrasive cloth or chamois Toilet Fixtures with Enviro Glaze Powder Coating Never use a plumber s snake to clear severe clogs The use of the tool will damage the finish scratch the paint and cause corrosion voiding the warranty Fixture must be dismounted from the structure sewer connection floor wall and the...

Отзывы: