background image

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SYDNEY  |  MELBOURNE  |  BRISBANE  |  PERTH  |  AUCKLAND

Australia

   1300 788 778   www.rba.com.au   |

   New Zealand

   0800 722 111  www.rbagroup.co.nz

1 of 20

RBA1882-100-001

 

'Nautilus' Dual Flush Valve Incl Large Mounting Plate

RBA1882-100-002 

'Nautilus' Dual Flush Valve Incl Small Mounting Plate

RBA1882-100-003 

'Nautilus' Dual Flush Valve Incl Small White Mounting Plate

RBA1882-100-005 

'Nautilus' Dual Flush Valve Incl Small Black Mounting Plate

RBA1882-100-007 

'Nautilus' Accessible Dual Flush Valve Incl Large Mounting Plate

RBA1882-100-008

 

'Nautilus' Dual Flush Valve Incl Indicator Rings, No Plate, Tile Fixed

AS 1172.2

W/M-40239

Global-Mark.com.au

Sourced/ Supplied under QMS

MODELS  

‘NAUTILUS’ WC ELECTRONIC DUAL WC FLUSH VALVE,  

   MAINS 

PRESSURE

As improvements in the design and performance of RBA products are continuous, specifications may be subject to change without notice.

The illustrations and descriptions herein are applicable to production as of the date of this Installation Instructions Sheet. Revised 12/22 © 2022 by RBA Group II/Model RBA1882-100-Series/1222

Содержание RBA1882-100-001

Страница 1: ...mall Black Mounting Plate RBA1882 100 007 Nautilus Accessible Dual Flush Valve Incl Large Mounting Plate RBA1882 100 008 Nautilus Dual Flush Valve Incl Indicator Rings No Plate Tile Fixed AS 1172 2 W...

Страница 2: ...01 Pg 4 RBA1882 100 002 Pg 5 RBA1882 100 003 Pg 6 RBA1882 100 005 Pg 7 RBA1882 100 007 Pg 8 RBA1882 100 008 Pg 9 2 1 Installation of the Flush Valve Assembly Pg 10 2 2 Installing the controller Pg 11...

Страница 3: ...available for site specific setting A 40mm loose nut and liner to suit PVC is supplied with each assembly Flush pipe is not supplied as a part of this assembly It is recommended that 2 x 45 bends may...

Страница 4: ...s Flush Valve Assembly 1 x RBA8012 999 727 T2 Controller for 3 Terminal WC s 3Amp Transformer Power Supply Plate Assembly 1 x RBA8010 999 010 Stainless Steel Piezo WC Full Flush 1 x RBA8010 999 011 St...

Страница 5: ...Nautilus Flush Valve Assembly 1 x RBA8012 999 727 T2 Controller for 3 Terminal WC s 3Amp Transformer Power Supply Plate Assembly 1 x RBA8010 999 010 Stainless Steel Piezo WC Full Flush 1 x RBA8010 99...

Страница 6: ...r Description 1 x RBA1882 100 Nautilus Flush Valve Assembly 1 x RBA8012 999 727 T2 Controller for 3 Terminal WC s 3Amp Transformer Power Supply Plate Assembly 1 x RBA1880 99 005 Small White Acrylic Fl...

Страница 7: ...r Description 1 x RBA1882 100 Nautilus Flush Valve Assembly 1 x RBA8012 999 727 T2 Controller for 3 Terminal WC s 3Amp Transformer Power Supply Plate Assembly 1 x RBA1880 99 005 Small White Acrylic Fl...

Страница 8: ...ilus Flush Valve Assembly 1 x RBA8012 999 727 T2 Controller for 3 Terminal WC s 3 Amp Transformer Power Pack Plate Assembly 1 x RBA1880 999 025 Large SS Flush Valve Plate Recess Kit to AS1428 1 1 x RB...

Страница 9: ...umber Description 1 x RBA1883 100 Nautilus Flush Valve Assembly 1 x RBA8012 999 727 T2 Controller for 3 Terminal WC s 3 Amp Transformer Power Pack Plate Assembly 1 x RBA8012 999 002 Half Full Flush In...

Страница 10: ...sembly removal should this be required Once installation heights have been established fit the Connecting Nut and vacuum breaker assembly to the ball valve and Nautilus Solenoid Fit the PVC cap and li...

Страница 11: ...unit Make electrical connections Connect wires of Half Flush piezo to the GND and SIG terminals of Sensor A Connect wires of Full Flush piezo to the GND and SIG terminals of Sensor B Connect Solenoid...

Страница 12: ...on Time s Position Time s Position Time s Position Time s 0 0 2 8 1 0 0 1 5 8 2 3 1 0 3 9 1 1 1 1 6 9 2 4 2 0 4 A 1 2 2 1 7 A 2 5 3 0 5 B 1 3 3 1 8 B 2 6 4 0 6 C 1 4 4 1 9 C 2 7 5 0 7 D 1 5 5 2 0 D 2...

Страница 13: ...vertical plane Consult RBA or a qualified hydraulic consultant for advice Fit the flush valve in the required position maintaining a minimum 700mm distance between the outlet of the vacuum breaker and...

Страница 14: ...vacuum breaker must be installed in the vertical plane Fit the flush valve in the required position maintaining a minimum 700mm distance between the outlet of the vacuum breaker and the centre line o...

Страница 15: ...talled in the vertical plane and consult RBA or a qualified hydraulic consultant for advice Fit the flush valve in the required position maintaining a minimum 700mm distance between the outlet of the...

Страница 16: ...A or a qualified hydraulic consultant for advice Assemble Piezo button and Flush ring escutcheon on to Piezo Ensure all components are securely fastened Pull Piezo cable through conduit from the botto...

Страница 17: ...t Remove face plate from mounting bracket Install mounting bracket into noggins Ensure fixing height allows direct access to Flush Valve as shown in image above Install Piezo buttons in face plate Mak...

Страница 18: ...red to suit water supply pressures from 300 500kPa and WELS Star ratings of 3 Star and 4 Star to suit comparable Watermark and WELS rated WC pans Please complete the following details for custom confi...

Страница 19: ...ut the plunger and spring assembly and clean them using a soft brush Use scale remover if required Reassemble components ensuring the spring is in the vertical position and reinstall the solenoid Filt...

Страница 20: ...issue Ensure the WELS rating of the WC pan is comparable to the WELS rating of the flush valve Incorrect timing setting of flush valve Master Trol at stated inlet pressure 6 0 Maintenance Spare Parts...