Technical Data

Inlet                        1/2” BSP (G1/2”)

Operating pressure    200 – 500 kPa

Flow Time                 7 seconds nominal (ALFA & RIO) 15 seconds (GOOSENECK)

Maximum Temp.       55ºC

Flow Rate                 4.5L per minute/5.5L per minute/8.5L per minute

Warranty                       2 years

Dimensions

261m

m

75m

m

51m

m

Ø45m m

G1/2"

147m m

185m

m

22º

RBA1043 SERIES - ‘ALFA’

FIGURE 1

RBA1044 SERIES - ‘RIO’

Ø34,5m m

Ø44m m

G1/2 "

20º

110m

m

125m m

51m

m

110m m

52m

m

Ø44m m

129mm

101m m

G1/2 "

80,5mm

62mm

93

m

m

51

m

m

112m m

Ø34,5m m

20º

RBA1047 SERIES - ‘GOOSENECK’

52m m

58m m

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SYDNEY  

|

  MELBOURNE  

|  

BRISBANE  

|  

PERTH  

|  

AUCKLAND

Australia   

1300 788 778   www.rba.com.au   

|   

New Zealand   

0800 722 111  www.rbagroup.co.nz

3

DESCRIPTION

Self closing pillar taps are designed for public areas, available in bright chrome

fi nish casted from dezincifi cation resistant brass alloy.

Single connection to water supply line, to either cold or pre-mixed water.

RBA 1043-600 ‘Alfa’ Basin Pillar Tap DR - Chrome - 6 Star WELS, 5.5Lpm

RBA 1043-400 ‘Alfa’ Basin Pillar Tap DR - Chrome - 4 Star WELS, 8.5Lpm

RBA 1044-600 ‘RIO’ Basin Pillar Tap DR - Chrome - 6 Star WELS, 4.5Lpm

RBA 1044-400 ‘RIO’ Basin Pillar Tap DR - Chrome - 4 Star WELS, 8.5Lpm

RBA 1047-600 ‘Gooseneck’ Basin Pillar Tap DR - Chrome - 6 Star WELS, 5.5Lpm

RBA 1047-400 ‘Gooseneck’ Basin Pillar Tap DR - Chrome - 4 Star WELS, 8.5Lpm

Installation

1) Installation must be carried out in accordance with local authority requirements.
2) Flush the line thoroughly, and remove all dirt and grit from the line before

    connecting the tap.
3) Install the tap in the basin, tightening lightly with spanner or grips.
4) Connection may be made with either fl exible S/S braided hose, or copper tube

    and compression fi ttings.
5) Before turning on the water remove the aerator and fl ush the tap.
6) Replace the aerator and check for leaks.
7) Fit appropriate coloured indicator to the handle.

PROBLEM  

  

          PROBABLE CAUSE     

                 SOLUTION

TROUBLE SHOOTING

No fl ow or low volume

*To remove the aerator and cartridge, see “Spare Parts” to choose appropriate tool. (Not supplied with the product).

Water fl ows continuosly

or Short/ long fl ow time

Leak under knob

Water turned off

Water outlet blocked

Cartridge blocked with dirt

Cartridge damaged
Valve direction incorrect

Cartridge damaged

Turn on 

Remove the blockage

Remove and clean*

Replace the cartridge*

Replace the cartridge*

Отзывы: