STEP-BY STEP FAULT FINDING PROCEDURE
METHODS OF USE
Motor Not Functioning
Motor Functioning But Not Spraying As Desired
Tank Is Leaking At The Side
1) Battery terminal is not inline with the sprayer's terminal.
2) Faulty battery or carbon formed on the terminals.
3) Loose connection of battery or switch terminal.
4) System short circuit.
5) Electric motor of the pump has decayed.
6) Charging was done correctly.
Switch 3 should be in ON position when charging, 3 pole connector is
connected properly.
1) Nozzle is blocked.
2) Disc is blocked.
3) Hose is blocked.(Rane cases)
4) Motor has worn out.
1) Valve (STMC-021-10045) is broken.
2) Washer (STTK-012-10019) has worn out or missing.
3) Hose clip is loose or broken.
For more detailed information on preparation and use of sprayers refer to the
manual supplied with the CDA sprayer.
Pre-mix the herbicide product in the required volume of water in the 10 litre
backpack (see section below on mixing and calibration) and attach the backpack to
the sprayer.
Hold the sprayer at an angle of between 30° - 40° to the ground with the atomiser
head positioned about 20cm above the weed. Soil age or soil surface. In this
position the atomiser head should be angle slightly forward to spray away from
operator. N.B. make sure the spray head is more that 60cm away from the operator
avoid contamination.