17
OUT CONTROL (84#3):
Sets / Resets outputs for the specific
State.
Output States:
1
– Output 4 (Saw Safe/Done)
2
– None
3
– Output 3 (Vertical Clamp)
4
– Output 3 (Vertical Clamp) &
Output 4 (Saw Advance)
Inputs:
DI1
– Start Saw
(Start/Stop Program)
DI2
– Saw Advanced
DI3
– Saw Retracted
DI4
– Cycle Start
LOGIC VALUE
–
DI2 & DI4
CHANGE DLY
(84#4):
Delay timer used as
an optional condition
to change states
State Triggers:
84#5 – Conditions
required for changing
to next state.
84#6 – Conditions
required to change to
a selected state.
84#7 – State changed
to when conditions in
84#6 are met.
Cycle start signal
received. Vertical
clamp moves down.
Saw is idle, waiting
for a cycle start sig-
nal. Saw Safe /
Done signal is on.
Vertical
clamp
down dwell time is
reached.
Saw
blade advances up.
Saw blade up prox.
input received. Saw
blade retracts
.
Saw blade down
prox.
input
on.
Cycle
completed,
waiting for cycle
start signal to reset.
Cycle start signal is
lost. Saw blade
and vertical clamp
retract, waiting for
cycle start signal to
resume.
CYCLONE 600 Manual VFD Display Codes
Note: Parameter 8434 is the dwell timer for the vertical clamp.
Default is 0.5 seconds.
Содержание Cyclone 600 VFD
Страница 22: ...22 CYCLONE 600 AUTOMATIC SCHEMATIC ...
Страница 23: ...23 CYCLONE 600 MANUAL SCHEMATIC ...
Страница 24: ...24 TROUBLESHOOTING ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 27: ...27 ...