Install the cover slide (with no front and back) by placing it into 

the Cover Slide Drawer. 

 

Retain the seal ring into the drawer. Replace with a new seal 

ring if it appears to be damaged.   

 

Reinstall  the  cover  drawer  into  the  head  by  depressing  the 

buttons on either side of the unit.   

 

Tighten the locking screw.   

 

Caution

Don’t take out the seal ring by digging its edge. 

This may damage the seal ring. 

 

4.2.2

 

Changing 3D Laser Head Cover Slide 

 

Open the outside cover of the jet tip 

 

Remove  the  cover  slide  by  depressing  the  buttons  on  either 

sides of the Cover Slide Drawer 

 

Remove the cover side from the drawer by applying 

pressure with your fingers to the surface of the cover 

slide, opposite the seal ring. The seal ring and cover 

slide will pop out. (save the seal ring) 

 

Clean or change the cover slide 

 

Install  the  cover  slide  by  placing  it  into  the  Cover 

Slide Drawer. 

 

Retain the seal ring into the drawer. Replace with a 

new seal ring if it appears to be damaged.   

 

Reinstall  the  cover  drawer  into  the  head  by 

depressing the buttons on either side of the unit.   

 

Rotate and close the jet tip   

 

4.2.3

 

Changing Collimating Lens Assembly 

Changing the collimating lens assembly can be performed while the head is mounted to the machine. This 

menu only covers the servicing of a Raytools’ collimator. Refer to third-party collimator’s    instructions for its 

servicing.   

Caution

Remove fiber with great care. Damaging fiber end may result in fiber replacement. 

Store fiber in such a manner to protect the end of the fiber from being damaged. 

 

  Wipe away loose debris from BT240 

  Using a 3 mm hex wrench, remove screws holding the 

fiber collimating assembly as shown in Figure 11. Take assembly 

to a clean area.   

 

Loosen  the  collimator  holder  and  take  out  the  seal ring  and  the 

collimator.   

 

Change or clean the collimator 

 

Install  the  collimator  in  order.  Tighten  the  seal  ring  and  thread 

them onto Module FRA.   

 

Reinstall components in reverse order.   

 

Check the tip centering, laser focus and image focus and adjust 

as needed.   

Figure 9 Changing 

Cover Slide

 

Figure 10 Inside Structure Of The 

Cover Drawer 

Figure 11 Collimating 

Module CM 

Содержание BT240 Series

Страница 1: ...BT240 Series Product Manual Add Buchmatt strasse 19 3400 Burgdorf Email sales raytools net Email peter cam raytools ch Tel 41 78 827 49 63 ...

Страница 2: ... V1 0 RayTools AG Copy Right 1 15 www raytools net Version V1 0 Date 2016 2 4 Historical Versions History Edition Date Description of change Editor Reviewer Date of Review V1 0 2016 01 27 Version Change Mandy Alex 2016 2 4 ...

Страница 3: ... aspects We apologize for your inconvenience here Index 1 Introduction 3 1 1 Product Features 3 1 2 The functions of the modules 3 2 Installation Mechanicals 5 2 1 Installation Of The Hole Site 5 2 2 Plumbing 5 2 2 1 Water cooling 5 2 2 2 Assist Gas 6 2 3 Fiber Connectors 6 2 4 Fiber Orientation Adjustment 6 3 Operation Mechanicals 8 3 1 Beam Centering 8 3 1 1 QCS Beam Centering 8 3 1 2 QBH Beam C...

Страница 4: ... thin mediate and thick steel cutting applications and other customized industrial laser processing environment A variety of flexible optical fiber connectors and optical collimating and re focusing equipments adapt it to most optical fiber laser devices in mainstream industry 1 1 Product Features Compact modular design efficiency water cooling system in annular and lateral gas flow easy to cut hi...

Страница 5: ...am centering 3 Module FM focus the collimated light beam to high power density focused light beam and move ups and downs to set the focal point 4 Module WM protect the optics protect the focusing lens from being damaged by residues and lengthen the life span of the optics 5 Module TM guide the focused light beam to the processing workpiece and spray high speed gas flow to achieve high quality cutt...

Страница 6: ...Plumbing 2 2 1 Water cooling BT240 processing heads are equipped with a water cooling circuit the direction of water moving in and out can be changed at will It is recommended that power levels greater than 500 watts use water cooling See Figure 3 for hose locations and numbers and the table on the right for recommended flow rates The cooling circuit is designed to be operated on either a closed l...

Страница 7: ...lled the fiber conductor Common fiber connectors include QBH QD LLK D and LLK B Aiming at conductor QD BT has 14 24 25 30 grip rings Other connections are available too Each fiber connectors has its own unique method of securely attaching the fiber Refer to the fiber type for specific instructions QBH connector is illustrated in Figure 1 Caution Great care must be taken to ensure the optics remain...

Страница 8: ... 1 with a wrench Rotate the QBH connector Once the fiber connector is oriented correctly tighten the clamping bolts and the set screw BT240 QCS connector input manual 1 loosen locking ring 1 and 2 2 Input the fiber connector horizontally 3 Tighten locking ring 1 and 2 Use a wrench if necessary Figure 4 2 Fiber Orientation ...

Страница 9: ...the screws with a 2 5mm hex wrench until the beam is centered in the tip One common method to make sure the beam is centered in the tip is to use a piece of translucent tape 1 Put a piece of translucent tape on the end of the Gas Jet Tip 2 Turn on the laser s internal red aiming beam and observe the position of the beam on the tape relative to the nozzle orifice Use the adjuster screws to center t...

Страница 10: ...point is 8 12 For example when the Focal Dial Knob is at 0 the position of the focal point will be at the end of the tip When the Focal Dial Knob is at 8 the position of the focal point will be 8mm in the tip To adjust the focus position follow this procedure Loosen the lock nut by rotating it counterclockwise Turn the Focus Dial Knob and adjust the focal distance according to the scale Once the f...

Страница 11: ...ht hand Scrub the lens in one direction from bottom to top of from left to right Do not scrub the lens back and forth to avoid secondary pollution Blow the surface of the lens with the air blowing machine Both sides should be cleaned Double check the lens after cleaning to make sure no cleansers absorbent cottons and impurities are left 4 2 Changing Lens The process should be finished in a clean e...

Страница 12: ...h a new seal ring if it appears to be damaged Reinstall the cover drawer into the head by depressing the buttons on either side of the unit Rotate and close the jet tip 4 2 3 Changing Collimating Lens Assembly Changing the collimating lens assembly can be performed while the head is mounted to the machine This menu only covers the servicing of a Raytools collimator Refer to third party collimator ...

Страница 13: ...the top See Figure 14 using the lens insertion tool unthread the lens holder Place the lens holder on a clean place Invert the lens holder and take out the lens Figure 13 Remove Module WM and TM Figure 14 Remove The Focusing Lens Sealing screw Plano convex lens 2 0mm TK spacer Plano convex lens Lens holder Figure 12 1 Installation Instruction D28mm PL CX PL CX CM Lens Holder Sealing screw convex c...

Страница 14: ...ion Then rotate the press cover Make two 2 mm location holes on the new ceramic head aligned with two location pins on the gas jet tip Hold the ceramic head and rotate the press cover Reassemble components in reverse order 4 3 2 Replacing 3D Module Tm Unscrew the outside cover of Module TM Unscrew the locking screws with a wrench Install the new Module TM on the laser head with screws Screw the ou...

Страница 15: ...ools AG Copy Right 14 15 www raytools net 4 3 3 Replacing Gas Jet Tip Unscrew the gas jet tip Insert the new gas jet tip Tinghten with appropriate force A calibration capacitor is needed after replacement Figure 17 Replace Module TM ...

Отзывы: