Synapsis Conning NX
Operation
___________________________________________________________________________________________________________________
27
2.4.6
Alerts
The alert window displays all current alarms, cautions and warnings with its time stamp
and source.
Figure 2-24
Alert Information
Table 2-6
Button Functions within Alert Window
Button
Function
All acoustic alerts mute for 30 seconds.
Expand or collapse the alert list.
Alerts are divided in different categories:
•
Category A
Alerts for which graphical information at the task station (such as Radar or ECDIS)
directly assigned to the function generating the alert is necessary, as decision
support for the evaluation of the alert-related condition. These alerts can only be
acknowledged at the task station.
•
Category B
Alerts where no additional information for decision support is necessary besides the
information which can be presented at the CAM-HMI. These alerts can be
acknowledged at the task station or at the CAM-HMI.
•
Category C
Alerts that cannot be acknowledged on the bridge but for which information is
required about the status and treatment of the alerts (e.g. certain alerts from the
engine). The SYNAPSIS INS does not generate own category C alerts, but
processes and displays category C alerts from connected systems.
Alerts are divided in different priorities: