Gyro Compass Standard 22 NX
1 Description
Edition:001
5
10000000015
andvisual alert announcements shall be avoided. It reduces the cognitive workload of the
operator by minimizing the presented information which is necessary to draw attention
toand to assess the situation.
On the bridge alerts are presented on the individual equipment and / or on a
Management Human Machine Interface (CAM-HMI)
.
Alerts are divided in different priorities:
• Emergency alarm
1
Highest priority of an alert. These Alarms show immediate danger to human life or to
the ship and its machinery and demand immediate action.
• Alarm
An alarm is a high-priority alert. Conditions requiring immediate attention and action
by the bridge team to avoid any kind of hazardous situation and to maintain the safe
operation of the ship.
• Warning
Conditions or situations which require immediate attention for precautionary reasons.
A warning makes the bridge team aware of conditions which are not immediately
hazardous, but may become so. (Warning may be escalated to alarm).
• Caution
Lowest priority of an alert. Awareness of a condition which still requires attention out of
the ordinary consideration of the situation or of given information.
Alerts are divided in different categories:
• Category A
Alerts for which graphical information at the task station (such as radar or ) directly
assigned to the function generating the alert. This is necessary as decision support for
the evaluation of the alert-related condition. These alerts can only be acknowledged at
the task station.
• Category B
Alerts where no additional information for decision support is necessary besides
the information which can be presented at the
acknowledged at the task station or at the
• Category C
Alerts that cannot be acknowledged on the bridge. These alerts require more
information about the status and treatment of the alerts (e.g. certain alerts from the
engine).
Note
The following list of alarms can only be displayed at the operating unit (130-626) or at a
CAM. The standard 22 NX itself cannot display this alarm itself.
1
The emergency alarm is not used in this device
Содержание Standard 22 NX
Страница 1: ...Gyro Compass Standard 22 NX Operator Manual Type 110 244 NG001 Edition 001 10000000015 ...
Страница 4: ...Gyro Compass Standard 22 NX Table of Contents 10000000015 II Edition 001 ...
Страница 6: ...Gyro Compass Standard 22 NX List of Figures 10000000015 IV Edition 001 ...
Страница 8: ...Gyro Compass Standard 22 NX List of Tables 10000000015 VI Edition 001 ...
Страница 10: ...Gyro Compass Standard 22 NX List of Abbreviations 10000000015 VIII Edition 001 ...
Страница 38: ...Gyro Compass Standard 22 NX 4 Care and Maintenance 10000000015 28 Edition 001 ...