Distribution Unit
138--118
DISTRIBUTION
UNIT
13
3647.DOC010302
Edition: Sept. 05, 2005
see Fig.7
see Fig.9
see Fig.10
see Fig.8
1
2
3
4
5
6 7 8 9 10 11
12
13
14
15
Fig.6:
I/O PCB (138--118.101. E10)
No.
Designation at the
I/O PCB E10
Remark
Fig.6/1
Switch B41
Test purpose only. Has to be always in closed
position.
Fig.6/2
Plug B2
TMC Connection IN/OUT
Fig.6/3
Plug B1
Connection to the Interface PCB
Fig.6/4
LED H38
35V DC for Step--function, lights up if present
Fig.6/5
Plug B10
Supply voltage 24V DC for the I/O PCB
Fig.6/6
Plug B4
Connection to flash
Fig.6/7,8,
9,10,11
LEDs
H42,H40,H41,H44,H43
Lights up if operating vo 5V DC and
+/-- 15V DC are present.
Fig.6/12
Push button B40
Reset CPU, after flashing
Fig.6/13
LED H1
Processor clock, blinks green
Fig.6/14
Switch B36
Not used, for future purpose
Fig.6/15
LED H50
Lights up red if the 35V DC for the Step--function
are switched off.
Содержание 138-118
Страница 5: ...Distribution Unit 138 118 DISTRIBUTION UNIT III 3647 DOC010302 Edition Sept 05 2005 ...
Страница 6: ...Distribution Unit 138 118 IV Edition Sept 05 2005 3647 DOC010302 ...
Страница 8: ...Distribution Unit 138 118 VI Edition Sept 05 2005 3647 DOC010302 ...
Страница 55: ...Distribution Unit 138 118 DISTRIBUTION UNIT 47 3647 DOC010302 Edition Nov 28 2005 4 2 3 6 Left blank ...
Страница 92: ...Distribution Unit 138 118 84 3647 DOC010302 Edition Sept 05 2005 ...
Страница 94: ...left blank ...
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......