Function description 
 

Vacuum measurement 

The SynchroKing 4S Mk2

 displays the vacuum of each individual channel in mmHg with a 

resolution of 2mmHg. Values under 20mmHg are supressed and the device will display ' - - - ' for 
any suppressed channels. If the channel is suppressed then it will be excluded  from the 
calculation of the average value of all active channels.  
 

Vacuum differential 

The SynchroKing 4S Mk2

 calculates the average value of all active channels and compares the 

individual value of each channel to this average. The deviation from average is displayed on the 
bar graph of the channel. Each bar represents 20 mmHg vacuum differential, whereas the two 
middle being lit indicate a pressure differential of less than 20mmHg (i.e the vacuum being 
practically the same in both manifolds). See Figure 3 for examples.

 

  

 
Dampening 

The SynchroKing 4S Mk2

 is equipped with a dampening function to produce a meaningful and 

readable display of the vacuum level. The vacuum in the inlet manifold of a running engine will 
fluctuate which will result in a rapidly updating readout which makes it virtually impossible to read 
the vacuum level. (Equivalent to a rapidly bouncing needle on a conventional gauge).  
 
To overcome this, the dampening function will store the average value of many measurements 
into the device memory and produce a display value based on these, resulting in a more stable 
readout (equivalent to a choke valve on a conventional gauge). The dampening factor is 