Device Description:
1. Main displays - The two main displays indicate the vacuum measured in the inlet
manifolds in mm of mercury [mmHg].
2. Bar displays - Each bar display indicates the level of vacuum
relative
to the average
vacuum in the inlet manifolds.
3. Pushbuttons ' + ' and ' - ' Used to set the desired dampening factor and initiate a manual
re-calibration
4. Power cable - Connects to the vehicle's battery to power the device.
5. 2 x M6 and 2 x M5 nipples - screw into the test ports of the vehicle's intake manifolds.
6. Set 1 2 hoses (not shown)
Figure 1 - Device Overview