Raytec VARIO2 w16 Скачать руководство пользователя страница 1

1  

        

www.rayteccctv.com

 

                                         

Raytec Global  Tel : +44(0) 1670 520055

 

                                                                                                       Americas Tel : +1 613 270 9990 

 

 

 

Installation  Guide 

Contents :  

Page 2   

Box Contents and Safety Information 

Page 3   

Short Guide and Factory Defaults 

Page 6   

LED Status Indicators – Feedback System 

Page 8   

VARIO Remote Controller (VRC) 

Page 10   

PIN Function Detail 

Page 12   

Manual Control Buttons  

Page 17    

Disabling Manual Buttons  

Page 18   

Power Up Functionality ; Re-Set Options 

Page 19   

Standard Bracketry 

Page 20   

Specifications Table 

Page 21   

Troubleshooting

  

Page 24 

Quick reference Tables for Manual Button Control and 
Remote control for PIN Set and Manual Button Disable/ 
Enable

 

 

Содержание VARIO2 w16

Страница 1: ...Status Indicators Feedback System Page 8 VARIO Remote Controller VRC Page 10 PIN Function Detail Page 12 Manual Control Buttons Page 17 Disabling Manual Buttons Page 18 Power Up Functionality Re Set Options Page 19 Standard Bracketry Page 20 Specifications Table Page 21 Troubleshooting Page 24 Quick reference Tables for Manual Button Control and Remote control for PIN Set and Manual Button Disable...

Страница 2: ...y Information Eye Safety IR Variants 850nm and 940nm Caution IR emitted from this product EN62471 Risk Group 2 Do not stare at the lamp Avoid exposure or use appropriate shielding eye protection Risk Group 2 for cornea lens infrared hazard For VAR i2 VAR i4 VAR i6 and VAR i8 variants hazard distance is 1500mm For VAR i16 hazard distance is 1840mm Max IR EHV Exposure Hazard Value 69 of Risk Group 2...

Страница 3: ...inator 3 Connect Illuminator to low voltage input 12 24V AC DC For Vario 16 variants 24V AC or DC only 4 6 Complete configuration wiring and final set up using manual push buttons on the illuminator or VARIO Remote Controller VRC VRC is an optional accessory Wiring six core cable White Yellow wires Photocell following contact Volt free output Non polarity sensitive Orange and Purple Wires Telemetr...

Страница 4: ...LS lenses will be clearly marked with the angle which they will produce when inserted into VARIO2 Please handle ILS lenses with care and do not touch optical film Only 1 ILS lens can be inserted into the product at anytime The product cannot accommodate multiple ILS lenses at the same time We would recommend that power is turned off when replacing ILS lenses Remove base plate from VARIO2 unit usin...

Страница 5: ...quired See page 18 for optional brackets Step 4 Telemetry Input Orange Purple As default the telemetry input will be wired together so that the unit turns on off automatically via the photocell If required to be activated by PIR or alarm system connect to appropriate volt free or TTL input Volt free input dry contact Non polarity sensitive short circuit light on TTL input Orange TTL ve Purple TTL ...

Страница 6: ...done with the optional VARIO Remote Control VRC LED Status Indicators Feedback system There are two tri coloured LEDs visible on the base of the VARIO2 illuminator The two LEDs provide important operating and status information The status information provided by each of these LEDs differs depending on which of the two operating modes the VARIO2 illuminator is in A Programming OR B Operating The LE...

Страница 7: ...ower Applied LHS FLASHING GREEN Remote control IR receiver problem Max VRC distance is 8m 26ft RHS FLASHING AMBER Indicates unit is in programming mode Programming Mode Only RHS SOLID AMBER Indicates that a valid command is being received from the remote Programming Mode Only LHS FLASHING RED Voltage supply problem detected LHS SOLID RED Illuminator fault detected All functions of the remote contr...

Страница 8: ...9990 VARIO Remote Controller VRC Optional Accessory Full instructions provided with VRC when supplied Note Reset button will not remove a PIN if one is present Note Unless detailed as part of the functionality if an invalid or blocked command is attempted both LEDs will flash RED ...

Страница 9: ...ication Number to be set for each lamp The PIN is set by using the Vario Remote Control VRC There are five buttons characters on the remote that can be used for this purpose Please see PIN Function Detail P 10 for full details on how to use the PIN function Note Unless detailed as part of the functionality if an invalid or blocked command is attempted both LEDs will flash RED ...

Страница 10: ...e characters the number of flashes will decrease until all characters are entered Note illegal characters will not be recognised and will not reduce the number of flashes When the PIN is set the illuminator will revert to Programming Mode When a PIN is Set Using the remote you can access the illuminator settings from operating mode by entering the PIN You cannot access Programming Mode by power re...

Страница 11: ...ogram mode without recycling the power Note If you forget your pin and need to make adjustments to the illuminator you need to do full Re set This requires power recycling whilst pressing the two manual control buttons at the same time This will restore factory default settings AND remove the previously programmed PIN Both LEDs will flash AMBER to signify that the process has been completed Note I...

Страница 12: ... control 1 Power Control 100 80 60 40 20 of maximum Factory Default is 100 2 Photocell Control 3 levels 25 Lux on 50 Lux off 10 Lux on 30 Lux off 5 Lux on 15 Lux off and photocell disable 3 Turn LED indicators on off 4 Illuminator Reset Options 5 Disable Remote Control and enter Operating Mode or Enable Remote Control and enter Programming Mode 6 Button Enable Disable ...

Страница 13: ...an invalid or blocked button push is attempted both LEDs will flash Red Manual Mode Selection by using LHS Button A momentary press of LHS button turn LHS LED solid RED and enters the user into the Illuminator Setting Modes In these modes you can change the following settings Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LE...

Страница 14: ... mode for the Illuminator Sequential presses of RHS BUTTON will take you through the available options to get to the required setting you want within that mode The Illuminator will stay at this setting level providing you do not push the RHS BUTTON again Once you have reached the required setting as shown in the following text either press the LHS BUTTON to cycle through the modes until LHS LED ex...

Страница 15: ...ding on which mode the Illuminator was in previously before selecting manual controls The following modes are available Power Level Mode LHS LED Solid RED RHS LED 20 Power Setting 1 Flash GREEN 40 Power Setting 2 Flashes GREEN 60 Power Setting 3 Flashes GREEN 80 Power Setting 4 Flashes GREEN 100 Power Setting 5 Flashes GREEN Photocell Level Mode LHS LED Solid GREEN RHS LED Low sensitivity 1 Flash ...

Страница 16: ...modes are available Illuminator Reset Mode LHS LED Flashing RED RHS LED Solid RED Keep RHS BUTTON depressed for 4 seconds RHS LED stays solid RED and then after 4 seconds both LEDs flash AMBER to show the illuminator has been reset This operation is equivalent to the factory reset button on the remote control It will not re set a PIN if one is present Remote Control Disable and Enter Operating Mod...

Страница 17: ...EDs will not change o Illuminator Configuration Modes can be accessed in the normal way by a continuous 4 second press RHS Button o Pushing this button will cause both indicator LEDS to flash RED Once the 30 minutes has expired any button push LHS or RHS will cause both indicator LEDs to flash RED and the manual buttons are fully disabled Disabling the Manual Buttons Using the Remote The manual bu...

Страница 18: ...ator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set options for resetting your VARIO2 illuminator Settings Re set Pressing and holding the RESET BUTTON on the remote control or using the manual buttons to complete a RESET will restore the factory settings to the illuminator Note If a PIN is present it will not be removed and the illuminat...

Страница 19: ... 1 613 270 9990 Standard Bracketry Supplied with the Product Model Dependant not to scale dimensions rounded to nearest mm Optional Bracketry not to scale other Bracketry also available VUB Pole VUB Wall VUB Plate VUB PSU Plate Wall Mount PTZ Mount Dome Mount Pole Mount ...

Страница 20: ...m 115ft 50m 164ft 36m 118ft 25m 82ft 24m 79ft 20m 66ft 120 65m 213ft 35m 115ft 45m 148ft 25m 82ft 30m 98ft 24m 79ft 18m 59ft 18m 59ft 12m 39ft Consumption 100W max 84W max 46W max 42W max 25W max 13W max 24W max 10W max 11W max Input 24V AC DC 12 24V AC DC 12 24V AC DC 12 24V AC DC Weight 3 1kg 6 8lbs 1 65kg 3 61lbs 950g 2 1lbs 600g 1 3lbs Number of LED s 48 24 12 9 12 6 6 Environment IP66 IP66 IP...

Страница 21: ...n if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably rated to product check page 19 for specifications If longer cables used ensure sufficient voltage is provided to allow for drops across the cable If OK Step 2 Illuminator Test Check current is being drawn amount of current will depend on power set...

Страница 22: ...eded Check the LED status indicators for the status of the illuminator The LED indicators will display differently depending on which mode the illuminator is in see below Programming mode RHS LED flashes AMBER 1 second on 1 second off LHS SOLID GREEN Power Applied LHS FLASHING GREEN Remote control IR receiver problem RHS FLASHING AMBER Indicates unit is in programming mode RHS SOLID AMBER Indicate...

Страница 23: ... unit may need to be reduced Programming may be disabled Enter PIN to retrieve control or RESET illuminator using one of the two RESET modes Battery failure Check battery on remote CR2025 Test 3 volt battery replace if necessary Ensure battery has clean contacts Remote failure Test with new remote Step 4 Call Raytec for further assistance Note down Model and serial number of illuminator Camera mak...

Страница 24: ...h sensitivity Solid Red indicates Photocell disabled Status Indicator LEDS On Off 3 x Push Each Push cycles between On and Off Solid Amber On Green Off Red Factory Re set Does not Re set PIN 1 x Long Push 4 Seconds Push and Hold until both LEDs flash Amber Flashing Red After 4s Flashing Amber Solid Red After 4s Flashing Amber Reverts to Programming Mode unless a PIN is present If a PIN is present ...

Страница 25: ...lluminator has two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled see Remote Control Instructions for more details Manual Buttons are always available in programming mode or if they have been disabled they can be enabled in programming mode Manual Buttons are available in operating mode provided they have not...

Страница 26: ...umbers are Power 5 Power 1 Min Photocell Smallest Moon Max Timer Full Red Circle Timer Disable The unit will NOT accept any invalid characters and the countdown will not reduce If valid characters are entered in the wrong order when entering a PIN the unit will accept the input and reduce the countdown but at the end of the countdown the illuminator will stay in operating mode show an error and th...

Страница 27: ... valid PIN character x 4 Green Intermitte nt Flashing Red Green Green Solid Amber Flashing Red counts down the No of valid characters required Flashing Amber Stays in Programming Mode after PIN created or changed Enter existing PIN Prog Mode Press Status Button for 4 seconds Enter valid PIN character x 4 Green Intermitte nt Flashing Red Green Green Solid Amber Flashing Green counts down the No of ...

Страница 28: ...28 www rayteccctv com Raytec Global Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 VA2 16 10 3 ...

Отзывы: