13
Hierarchy of Photocell vs. Telemetry
•
If the telemetry function is enabled, then the photocell must detect that it is
dark for the telemetry function to operate.
•
The photocell overrides the telemetry function during the day. If the external
input/telemetry function needs to be operated 24 / 7, then the photocell
function should be disabled from the settings / groups page.
•
If the external input/telemetry is not active, then the unit will follow the
photocell settings.
The system requires 15 seconds of light to deactivate the photocell and turn the
illuminators off to avoid accidental turn off of the illuminators via car headlights or
torches.
If illuminators are in groups, the following rules apply:
-
ANY sending illuminator within a group which says it is dark will turn all the
illuminators in the group on (subject to local illuminator settings)
-
ALL illuminators in the group need to say it is light before all the group
illuminators will go off together (subject to local conditions)
Log-in, Security & Basic Illuminator Setup
Log-in using Operator or Administrator user names and passwords. Operator has
limited access rights. Administrator has full access rights.
Defaults (User Names & Passwords are case sensitive):
Users & Passwords
Name
Password
Operator
user
password
Administrator
admin
password
In order to maintain maximum security of your system, we recommend you change
the passwords at the earliest opportunity (for further information, please see page 49
of full installation instructions).
Содержание VARIO2 IP 16 Series
Страница 3: ...3 has a HTTP API to control the illuminator via HTTP commands...
Страница 4: ...4...
Страница 30: ...30 Unit Name and Group Name can both be edited by entering a new value in their fields...
Страница 60: ...60 Log Off We recommend after using the illuminator web interface that users log off using the Log Off Page...
Страница 64: ...64 Version Vario2 IP 16 Instruction Guide Rev 1 0 0 Full...