background image

4

Step 2. Mounting Illuminator

VARIO is delivered as standard with bracket at the bottom of the unit. This can be 
moved to top the of unit if required. See page 6 for optional brackets

Step 3 & 4. Connect to low voltage power supply and input 12/24 AC/DC

Step 5. Telemetry Input (Orange & Purple)

As default will be wired together for standard photocell controlled on/off operation. 
If required to be activated by PIR or alarm system, connect to appropriate, volt-free 
input or TTL. Telemetry Input for remote switch or input. Volt free input/dry contact: 
Non polarity sensitive, short circuit = light on

TTL input: Orange = TTL +ve, Purple = TTL –ve (GND)
                 0V = Light on, 3V = Light off

Step 6. Photocell following output (White & Yellow)

Volt free output - normally open (day) to normally closed (night). Connect direct to 
camera if required to control switchover of day/night cameras.

1

2

3

Position illuminator 

adjacent to camera and point 
towards scene (Optional 
night set-up for optimum 
image performance)

Adjust vertical position of 

lamp to ensure full field of 
view illuminated

Tighten all fixings

TARGET

  

1

1

2

2

3

Mount illuminator 

Connect Illuminator to low voltage power supply: 
Installers can extend or reduce lead length using 
appropriate cable and weather proof box

Input 12-24V DC/ 24V AC

Note:

    Red = 

positive

             Black = 

negative

Содержание Vario I2

Страница 1: ...Page 7 Bracketry Page 8 Specifications Page 9 11 Troubleshooting VARIO illuminator with 35 beam angle IHD 60 beam angle IHD VARIO Remote Controller for additional programming of the unit 80 beam angle IHD 120 beam angle IHD Box Contents Accessories optional Installation and Setup guide VARIO Series VARIO w8 VARIO i8 VARIO w4 VARIO i4 VARIO w2 VARIO i2 ...

Страница 2: ... configuration and final set up using VARIO Remote Controller VRC this is an optional accessory Factory Default Set Up 35 Beam Angle Max 100 Power Telemetry Input closed Photocell sensitivity MID Status LEDs ON Programming function will auto disable after 4 weeks Photocell Cable Breather Gland Wiring six core cable White Yellow wires Photocell following contact Volt free output Non polarity sensitiv...

Страница 3: ...e when inserted into VARIO Please handle IHD lenses with care and do not touch optical film Only 1 IHD lens can be inserted into the product at anytime The product cannot accommodate mutliple IHD lenses at the same time We would recommend that power is turned off when replacing IHD lenses Remove base plate from VARIO unit using 2 5mm allen hex key Insert required IHD lens and re attach base plate fi...

Страница 4: ...on polarity sensitive short circuit light on TTL input Orange TTL ve Purple TTL ve GND 0V Light on 3V Light off Step 6 Photocell following output White Yellow Volt free output normally open day to normally closed night Connect direct to camera if required to control switchover of day night cameras 1 2 3 Position illuminator adjacent to camera and point towards scene Optional night set up for optim...

Страница 5: ...perational requirements Timer Setting The timer function allows the illuminator to be triggered via the telemetry input and remain on for a pre defined period of time Photocell Disable Lamp operates from telemetry input only Timer disable 30 mins 10 mins 3 mins 1 min Selects dimming function on telemetry wires Restores Factory Default Settings Must be depressed for 4 seconds LED Status Indicator Tu...

Страница 6: ...d a FLASHING RED status LED indicates that there is a problem with the input voltage Please note once the voltage problem has been corrected the user must disable remote control set up or power the unit on and off to stop the RED status LED flashing SOLID GREEN status LED indicates unit has power applied FLASHING GREEN status LED indicates a problem with the remote control IR receiver The maximum r...

Страница 7: ...ketry not to scale VARIO 2 series VARIO 4 series VARIO 8 series Standard Bracketry not to scale dimensions rounded to nearest mm Wall Mount Dome Mount Ptz Mount Pole Mount 51mm 53mm 53mm 47mm 72mm 104mm 52mm 56mm 53mm ...

Страница 8: ...m 120 Consumption 48W max 24W max 12W max Input 12 24V AC or DC 12 24V AC or DC 12 24V AC or DC Weight 1 8kg 4lbs 1kg 2 2lbs 650g 1 4lbs Environment IP66 IP66 IP66 Dimensions L x W x D 135 x 180 x 68 2 mm 5 x 7 x 3 2 100 x 135 x 66mm 4 x 5 x 2 5 75 x 100 x 64mm 3 x 4 x 2 5 Cable Length 2 5m 2 5m 2 5m VARIO Specifications Infra Red Series White Light Series Standards Radiated Conducted Emissions EN5...

Страница 9: ...ee Infra Red lamps working in high brightness conditions Ensure power supply is suitably rated to product check page 8 for specifications If longer cables used ensure sufficient voltage is provided to allow for drops across the cable If OK Step 2 Lamp Test Check current is being drawn amount of current will depend on power setting of unit Please note use appropriate multimeter depending on how the u...

Страница 10: ... LED flashes 1 second on 1 second off SOLID GREEN Power Applied FLASHING GREEN Remote IR receiver problem SOLID RED Internal LED Fault Detected FLASHING RED Voltage supply problem detected Please note once the voltage problem has been corrected the user must disable remote control set up or power the unit on and off to stop the red status LED flashing SOLID AMBER Valid command being received this re...

Страница 11: ...itions distance between remote and unit may need to be reduced Battery failure Check battery on remote CR2025 Test 3 volt battery replace if necessary Ensure battery has clean contacts Remote failure Test with new remote Step 4 Contact us for assistance Note down Model and serial number of illuminator Camera make and model Lens make and model If the RayLED lamp or remote control is still not deliv...