Raytec Technical Support:  

Europe / Middle East: +44 (0) 1670 528446 

Americas: +1 (281) 438 3599 

Mains 

In 

LED 

Output 

x2 

Additional Information for UL 1838 & CSA 22.2 No9.0 

  Suitable for indoor and outdoor use. 
  Suitable for use in wet locations. 
  Suitable for mounting on flammable surfaces. 
  Suitable for combustrible surface use. 
  Suitable for ambient not exceeding 35

o

 
Do not connect PSU to an ungrounded supply. 
Do not intall within 10ft of pool or spa. 
Do not use with dimmers. 
 
Do not connect two or more power supplies in parallel. 
 
This product must be installed by a person familiar with the construction and operation of the product and 
the hazards involved, in accordance with the applicable installation code. 
 
The device is accepted as a component of a landscape lighting system where the suitability of the  
combination shall be determined by CSA or local inspection authorities having jurisdiction. Such systems 
should be protected by a ground fault circuit interrupter of the Class A type. 
 
 
 
 
 
 

 

RAYMAX and RAYLUX 

25 / 50 models: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LED Outputs Polarity sensitive

Telemetry Input – 
requires zero volt, 
latched input 

Photocell 
Sensitivity 
Adjust 

Power 
Adjust 

Photocell 

Main Input  
100V to 240 AC 

Содержание RAYLUX RL100

Страница 1: ...Europe Middle East 44 0 1670 528446 Americas 1 281 438 3599 Narrow angle using Adaptive Illumination Wide angle using Adaptive illumination specifications subject to change without notice RAYMAX RAYLUX Installation Instructions ...

Страница 2: ...universal 20W AC 100 265 universal 10W Fuse 2 5A anti surge 2 5A anti surge 1A anti surge 1A anti surge Output 4 2A 14V 2 8A 14V 1 4A 14V 0 7A 14V Adjustable Power 10 100 10 100 10 100 10 100 Weight 1 85 kg 1 65 kg 0 9 kg 0 8 kg Dimensions L x W x D 160 x 160 x 81 160 x 160 x 81 160 x 100 x 61 160 x 100 x 61 Drilling Dimensions 4 x M4 holes 145 x 123mm 4 x M4 holes 145 x 123mm 4 x M4 holes 145 x 6...

Страница 3: ...s on the PSU 13 CAUTION LED output is polarity sensitive Black negative ve Red positive ve 14 CAUTION For 200 100 and 50 series units RAYMAX and RAYLUX connect both LED units before initializing PSU 15 CAUTION For 300 series units RAYMAX and RAYLUX ensure all three LED panels are connected to the PSU before turning on 16 Photocell Control Telemetry The PSU is set up for automatic photocell operati...

Страница 4: ... more power supplies in parallel This product must be installed by a person familiar with the construction and operation of the product and the hazards involved in accordance with the applicable installation code The device is accepted as a component of a landscape lighting system where the suitability of the combination shall be determined by CSA or local inspection authorities having jurisdictio...

Страница 5: ...es a different switch mode than the model shown The model shown is the RM100 and RL100 PSU Telemetry Input requires zero volt latched input Photocell following contact volt free non polarity sensitive Premium PSU only 12v dc power output Premium PSU Only LED Outputs Polarity sensitive Universal 100 240V AC auto sensing Photocell Photocell Sensitivity Power Adjust Telemetry Input requires zero volt...

Отзывы: